9. CONNECTION TO RKC TEMPERATURE CONTROLLER
9.5 Temperature Controller Side Setting
9 - 45
C
O
NN
ECTION T
O
RK
C TEMPE
R
A
T
UR
E CON
T
R
O
LLER
9
(3) Unit address settings
Set the unit address using the unit address setting
switch.
(4) Interval time settings
Configure the interval time setting using the RKC
communication setting tool (WinPCI).
After the communication is started, set as follows.
For the using method of RKC communication setting
tool, refer to the following.
RKC communication setting tool user's manual
9.5.5
Connecting to CB Series
(1) Communication settings
*1
When the setting value is set to 0, a communication is not
made.
*2
Adjust the settings with GOT settings.
(2) Communication setting mode
Set the communication setting mode using the
operation panel of the CB series main unit.
For details of the communication setting mode, refer to
the following.
CB series "Communication Instruction Manual"
9.5.6
Connecting to FB Series
(1) Communication settings
*1
Items and setting range are common to communication 1
and communication 2.
*2
When the setting value is set to 0, a communication is not
made.
*3
Adjust the settings with GOT settings.
(2) Data bit configuration
(3) Communication setting mode
Set the communication setting mode using the
operation panel of the FB series main unit.
For details of the communication setting mode, refer to
the following.
FB series "Communication Instruction Manual"
Setting item
Set value
Instrument
0
CFG file
ZCOM_rkc.cfg
Communication 1 interval time
0 to 250ms
Communication 2 interval time
Item
Setting range
Device address
*1
1 to 99
Communication speed
*2
2: 9600bps
3: 19200bps
Data bit configuration
0: 8/1/None
6: 8/1/Even
7: 8/1/Odd
Interval time
0 to 150
Unit address setting switch
Setting range : 0 to F
COM
Item
*1
Setting range
*1
Communication protocol
1: MODBUS
Device address
(Slave address)
*2
1 to 99
Communication speed
*3
96: 9600bps
19.2: 19200bps
38.4: 38400bps
Data bit configuration
(2) Refer to the data bit configuration.
Interval time
0 to 250
Set value
Data bit
Parity bit
Stop bit
8n1
8
None
1
8n2
8
None
2
8E1
8
Even
1
8E2
8
Even
2
8o1
8
Odd
1
8o2
8
Odd
2
Summary of Contents for GOT2000Series
Page 2: ......
Page 17: ...A 15 REVISIONS WARRANTY...
Page 52: ...1 30 1 PREPARATORY PROCEDURES FOR MONITORING 1 6 Checking for Normal Monitoring...
Page 54: ......
Page 78: ...3 10 3 CONNECTION TO HITACHI PLC 3 6 Device Range that Can Be Set...
Page 100: ...4 22 4 CONNECTION TO FUJI PLC 4 7 Precautions...
Page 174: ...7 24 7 CONNECTION TO YOKOGAWA PLC 7 4 Device Range that Can Be Set...
Page 262: ...9 54 9 CONNECTION TO RKC TEMPERATURE CONTROLLER 9 7 Precautions...
Page 280: ...10 18 10 CONNECTION TO ALLEN BRADLEY PLC 10 4 Device Range that Can Be Set...
Page 296: ...11 16 11 CONNECTION TO GE PLC 11 7 Precautions...
Page 308: ...12 12 12 CONNECTION TO LS INDUSTRIAL SYSTEMS PLC 12 6 Device Range that Can Be Set...
Page 332: ...14 18 14 CONNECTION TO SIEMENS PLC 14 4 Device Range that Can Be Set...
Page 334: ...REVISIONS 2...
Page 337: ......