App - 31 App - 31
MELSEC
APPENDIX
(Example) Using the following system configuration example when the
transmission rate is 10 Mbps (assuming that there is no faulty station
or transient transmission.)
Master
station
Remote
I/O station
Remote
I/O station
Remote
device station
Intelligent
device station
Local
station
1: Occupies 1 station
2: Occupies 2 stations
3: Occupies 4 stations
Station
number 1
1
Station
number 2
2
Station
number 4
3
Station
number 12
1
Station
number 8
3
BT = 0.8
ST = 2000
NI = 12 16
1) 800 + (2 15) = 830
NW = 11 16
2) 900 + (2 50) = 1000
N = 5
3) 1200 + (8 100) = 2000
ni = 12
a = 2, b = 2, c = 8
nw = 10
LS = 0.8 {29.4 + (16 4.8) + (16 9.6) + (5 32.4) + (12 4.8)
+ (10 9.6)} + 2000
= 2556.2 [µs]
= 2.56 [ms]