16 - 12 16 - 12
MELSEC
16 TROUBLESHOOTING
Event ID
(HEX)
Error message
Corrective action
295
(127
H
)
The Board WDT error had occurred. 3
It might be failed CC-Link Ver.2 board.
Consult your local Mitsubishi representative.
296
(128
H
)
The CLOCK STOP error had occurred.
297
(129
H
)
The Target Abort error had occurred on the PCI bus.
304
(130
H
)
The Data Parity error had occurred on the PCI bus.
• Restart the personal computer.
• Check the board installation status.
• If the board operates normally on other
personal computer, the personal computer
may have any problems. In this case, repair or
replace the personal computer.
• It might be failed CC-Link Ver.2 board.
Consult your local Mitsubishi representative.
305
(131
H
)
The board is not operated normally because the sleep mode, hibernation
mode, and fast startup is not supported by the board.
Change the Power Option not to enter the
sleep mode, hibernation mode, or disable the
fast startup function and restart the personal
computer.
306
(132
H
)
The Board error was detected by the hardware self-diagnosis.
• Remove other option boards.
• Take corrective action for driver WDT error
occurrence. (Refer to Section 16.4.2)
• Restart the personal computer.
• Check if data is not written to the numbers
not listed in the list of link special relays (SBs)
and the list of link special registers (SWs).
(Refer to Appendix 2)
• Check the board installation status.
• If the board operates normally on other
personal computer, the personal computer
may have any problems. In this case, repair or
replace the personal computer.
• It might be failed CC-Link Ver.2 board.
Consult your local Mitsubishi representative.
1281
(501
H
)
Initialization of the
CC-Link board
has failed.
DUMP
value
Error description (details)
—
01h
There was no response from hardware.
Replace the CC-Link Ver.2 board.
67h
68h
Duplicate IRQ or memory assignment.
2
Remove other option boards.
03h
There was no response from hardware.
Replace the CC-Link Ver.2 board.
04h
21h
Handshaking with the shared memory area
has failed.
Restart. If the error persists, replace the
board.
66h
There was no response from hardware.
Replace the CC-Link Ver.2 board.
DUMP value ................................................ Value of the first 1 byte in the detailed data description area
*1: When this event error occurs on the event viewer of the operating system, change the BIOS Setup setting
as follows and reboot the PC.
(BIOS Setup items)
• Plug & Play O/S: [YES] [No]
• Reset Configuration Data: [No] [YES]
*2: This event error may occur when the PCI bus controller is not functioning correctly.
This error may also occur if the USB driver is not functioning correctly. In this case, reinstall the USB driver
and make sure that it functions correctly.
*3: This event error occurs on the event viewer by setting the hardware test mode using mdBdModSet
function or executing hardware test with CC-Link Ver.2 utility.
Summary of Contents for Q80BD-J61BT11N
Page 2: ......
Page 34: ...1 10 1 10 MELSEC 1 OVERVIEW MEMO ...
Page 54: ...3 12 3 12 MELSEC 3 SPECIFICATIONS MEMO ...
Page 124: ...5 16 5 16 MELSEC 5 PROCEDURE BEFORE STARTING THE DATA LINK MEMO ...
Page 160: ...9 2 9 2 MELSEC 9 MELSEC DATA LINK LIBRARY MEMO 9 ...
Page 200: ...12 16 12 16 MELSEC 12 COMMUNICATION BETWEEN THE MASTER STATION AND LOCAL STATIONS MEMO ...
Page 355: ...App 93 App 93 MELSEC APPENDIX MEMO ...
Page 361: ......