MDS-E/EH Series Instruction Manual
6 Spindle Adjustment
358
IB-1501229-F
(2) Setting of the temperature compensation time constant (SP236)
[1] Set SP236(WIH)=10. (Leave the setting of SP235 unchanged.)
[2] Run the program (acceleration/deceleration) that you created in [5] of (1), and continue until [Temperature
(°C)] on the spindle monitor screen reaches 100 (or the upper limit of temperature in practical use).
[3] Stop the spindle when [Temperature (°C)] on the spindle monitor reaches 100 (or the upper limit of
temperature in practical use). Then wait until [Temperature (°C)] drops to 80 (or the upper limit of temperature
in practical use - 20°C).
[4] When [Temperature (°C)] on the spindle monitor reaches 80 (or the upper limit of temperature in practical use
- 20°C), run the program (acceleration/deceleration) you created in [5] of (1) by one cycle. Adjust SP236(WIH)
as follows according to the value of [AFLT gain (dB)] on the spindle monitor screen during the operation.
• When [AFLT gain (dB)] is smaller than 90:
Increment SP236(WIH) by 2 at a time and perform [2]
• When [AFLT gain (dB)] is 111 or greater:
Decrement SP236(WIH) by 2 at a time and perform [2].
[5] The SP236(WIH) value to be obtained while [AFLT gain (dB)] is in the range of 90 to 110 is the result of the
final adjustment.
[6] Set SP226 bit8 to 0. (Change SP226(SFNC6) from 0100 to 0000.)
*Change SP153 and SP185 back to the original settings and turn OFF and ON the NC
power.
CAUTION
Check the monitor screen to make sure that the motor has reached the maximum rotation speed in constant output during
execution of the created program.
* "Maximum rotation speed in constant output" is the maximum speed at which the short-time rated output will not drop
lower than the motor’s specified output. (Refer to the motor output specifications.)
If the machine’s specified speed is lower than the motor’s maximum speed in constant output, the machine’s specified
speed serves as the maximum rotation speed.
Summary of Contents for MDS-E
Page 1: ......
Page 3: ......
Page 15: ......
Page 17: ......
Page 19: ......
Page 21: ......
Page 31: ......
Page 32: ...1 IB 1501229 F 1 Installation ...
Page 76: ...45 IB 1501229 F 2 Wiring and Connection ...
Page 132: ...101 IB 1501229 F 3 Safety Function ...
Page 142: ...111 IB 1501229 F 4 Setup ...
Page 277: ...MDS E EH Series Instruction Manual 4 Setup 246 IB 1501229 F ...
Page 278: ...247 IB 1501229 F 5 Servo Adjustment ...
Page 351: ...MDS E EH Series Instruction Manual 5 Servo Adjustment 320 IB 1501229 F ...
Page 352: ...321 IB 1501229 F 6 Spindle Adjustment ...
Page 404: ...373 IB 1501229 F 7 Troubleshooting ...
Page 455: ...MDS E EH Series Instruction Manual 7 Troubleshooting 424 IB 1501229 F ...
Page 456: ...425 IB 1501229 F 8 Maintenance ...
Page 475: ...MDS E EH Series Instruction Manual 8 Maintenance 444 IB 1501229 F ...
Page 476: ...445 IB 1501229 F 9 Power Backup System ...
Page 494: ...463 IB 1501229 F 10 Appx 1 Cable and Connector Assembly ...
Page 504: ...473 IB 1501229 F 11 Appx 2 D A Output Specifications for Drive Unit ...
Page 514: ...483 IB 1501229 F 12 Appx 3 Protection Function ...
Page 523: ...MDS E EH Series Instruction Manual 12 Appx 3 Protection Function 492 IB 1501229 F ...
Page 524: ...493 IB 1501229 F 13 Appx 4 Compliance to EC Directives ...
Page 528: ...497 IB 1501229 F 14 Appx 5 EMC Installation Guidelines ...
Page 540: ...509 IB 1501229 F 15 Appx 6 Higher Harmonic Suppression Measure Guidelines ...
Page 550: ......
Page 554: ......