MDS-E/EH Series Instruction Manual
6 Spindle Adjustment
333
IB-1501229-F
Relation between SP071 (variable current limit during deceleration, lower limit value) and
SP072 (variable current limit during deceleration, break point speed)
【
#13071
】
SP071 DIQM Variable current limit during deceleration, lower limit value
Set this parameter to adjust the deceleration time by changing the current limit value during
deceleration depending on the motor speed.
As shown below, set the lower limit rate of the current limit in SP071 (DIQM), and use with SP072
(DIQN).
When DIQM is set to 100%, the standard current limit value in deceleration (SP152) is applied.
---Setting range---
0 to 999 (%)
【
#13072
】
SP072 DIQN Variable current limit during deceleration, break point speed
Set this parameter to adjust the deceleration time by changing the current limit value during
deceleration depending on the motor speed.
As shown below, set the lower limit rate of the current limit in SP071 (DIQM), and use with SP072
(DIQN).
When DIQM is set to 100%, the standard current limit value in deceleration (SP152) is applied.
---Setting range---
1 to 32767 (r/min)
100
SP072
SP071
0
0
<1>
<2>
SP072
SP026
<1> SP152(SP184)×SP071/100
<2> SP152(SP184)
0
Current limit
Motor rotation speed
Max. rotation speed
Decreasing current value
”100” is the setting value for the current limit
during regeneration (SP152 (high-speed coil),
SP184 (low speed coil)).
(1) Rotation speed – Decreasing current value curve
Time(s)
Motor rotation speed
Deceleration time
q axis command/FB
(2) Rotation speed/current command FB waveform
DIQN
0
DIQM
100%
SP152
Motor speed
DIQN
0
DIQM
100%
SP152
Motor speed
Summary of Contents for MDS-E
Page 1: ......
Page 3: ......
Page 15: ......
Page 17: ......
Page 19: ......
Page 21: ......
Page 31: ......
Page 32: ...1 IB 1501229 F 1 Installation ...
Page 76: ...45 IB 1501229 F 2 Wiring and Connection ...
Page 132: ...101 IB 1501229 F 3 Safety Function ...
Page 142: ...111 IB 1501229 F 4 Setup ...
Page 277: ...MDS E EH Series Instruction Manual 4 Setup 246 IB 1501229 F ...
Page 278: ...247 IB 1501229 F 5 Servo Adjustment ...
Page 351: ...MDS E EH Series Instruction Manual 5 Servo Adjustment 320 IB 1501229 F ...
Page 352: ...321 IB 1501229 F 6 Spindle Adjustment ...
Page 404: ...373 IB 1501229 F 7 Troubleshooting ...
Page 455: ...MDS E EH Series Instruction Manual 7 Troubleshooting 424 IB 1501229 F ...
Page 456: ...425 IB 1501229 F 8 Maintenance ...
Page 475: ...MDS E EH Series Instruction Manual 8 Maintenance 444 IB 1501229 F ...
Page 476: ...445 IB 1501229 F 9 Power Backup System ...
Page 494: ...463 IB 1501229 F 10 Appx 1 Cable and Connector Assembly ...
Page 504: ...473 IB 1501229 F 11 Appx 2 D A Output Specifications for Drive Unit ...
Page 514: ...483 IB 1501229 F 12 Appx 3 Protection Function ...
Page 523: ...MDS E EH Series Instruction Manual 12 Appx 3 Protection Function 492 IB 1501229 F ...
Page 524: ...493 IB 1501229 F 13 Appx 4 Compliance to EC Directives ...
Page 528: ...497 IB 1501229 F 14 Appx 5 EMC Installation Guidelines ...
Page 540: ...509 IB 1501229 F 15 Appx 6 Higher Harmonic Suppression Measure Guidelines ...
Page 550: ......
Page 554: ......