54. CONNECTION TO ALLEN-BRADLEY PLC
54.2 Serial connection
54 - 11
(3) AB Control/CompactLogix
(4) AB SLC500
*1
Do not specify the same value for the adapter address and
host address.
POINT
POINT
POINT
(1) Communication interface setting by Utility
The communication interface setting can be
changed on the Utility's [Communication setting]
after writing [Communication Settings] of project
data.
For details on the Utility, refer to the following
manual.
11. COMMUNICATION INTERFACE SETTING
(COMMUNICATION SETTING)
(2) Precedence in communication settings
When settings are made by GT Designer3 or the
Utility, the latest setting is effective.
54.2.6 PLC side setting
POINT
POINT
POINT
ALLEN-BRADLEY PLC
For details of ALLEN-BRADLEY PLCs, refer to the
following manuals.
Manuals for ALLEN-BRADLEY PLCs
Directly connecting to the CPU
*1
Set the Baud Rate according to the transmission speed
setting on the GOT side.
*2
Set the Error Detection according to the sum check format
setting on the GOT side.
Connecting to DH485 network via adapter
(1770-KF3) (Setting of Adapter)
*1
Set the Baud Rate according to the transmission speed
setting on the GOT side.
*2
Set the Error Detection according to the sum check format
setting on the GOT side.
*3
For the Maximum Node Address, set the same address as
the Maximum Node Address on the DH-485 network.
*4
Set the DH-485 Node Address according to the Host
Address on the GOT side.
Set a unique DH-485 Node Address so that it does not
conflict with the Node Address of the PLC CPU on the DH-
485 network.
Item
Description
Range
Transmission
Speed
Set this item when change the
transmission speed used for
communication with the connected
equipment.
(Default: 19200bps)
9600bps,
19200bps,
38400bps,
57600bps
115200bps
Data Bit
Set this item when change the data length
used for communication with the connected
equipment. (Default: 8bit)
7bit/8bit
Stop Bit
Specify the stop bit length for
communications. (Default: 1bit)
1bit/2bits
Parity
Specify whether or not to perform a parity
check, and how it is performed during
communication. (Default: None)
None
Even
Odd
Sum Check
Type
Specify the format in which the sum check
is performed during communication when
performing sum check. (Default: BCC)
BCC,
CRC16
Retry
Set the number of retries to be performed
when a communication error occurs.
(Default: 3times)
0 to 5times
Timeout Time
Set the time period for a communication to
time out. (Default: 3sec)
3 to 30sec
Adapter
Address
Specify the adapter address (station No. of
the PLC that the GOT will monitor) in the
connected network. (Default: 0)
0 to 254
Host Address
Specify the host address (station No. of the
adapter to which the GOT is connected) in
the connected network. (Default: 0)
0 to 254
Delay Time
Set this item to adjust the transmission
timing of the communication request from
the GOT. (Default: 0ms)
0 to 300ms
Item
Description
Range
Transmission
Speed
Set this item when change the transmission
speed used for communication with the
connected equipment. (Default: 19200bps)
4800bps,
9600bps,
19200bps
Adapter
Address
*1
Specify the adapter address (station No. of
the PLC that the GOT will monitor) in the
connected network. (Default: 0)
0 to 31
Host
Address
*1
Specify the host address (station No. of the
adapter to which the GOT is connected) in
the connected network. (Default: 1)
1 to 31
Item
Settings
SLC500
Series
MicroLogix
1000/1200/
1500 Series
Control/
Compact/
FlexLogix
Series
Baud Rate
*1
4800bps,
9600bps,
19200bps
4800bps,
9600bps,
19200bps,
38400bps
4800bps,
9600bps,
19200bps,
38400bps
Parity
EVEN
NONE
NONE
Control Line
NO HANDSHAKING
Communication
Driver
DF1 HALF-DUPLEX SLAVE
Duplicate Packet
Detection
DISABLE
Station Address
0
Error Detection
BCC
BCC, CRC
*2
BCC, CRC
*2
Item
Settings
Baud Rate
*1
4800bps, 9600bps, 19200bps
Parity
Even
Flow Control
Disable (No Handshaking)
DF1 Device Category
DF1 half-duplex slave, local mode
Error Detection
*2
BCC
DH-485 Baud Rate
19200bps
Maximum Node Address
1 to 31
*3
DH-485 Node Address
0 to 31
*4
Summary of Contents for GT14
Page 1: ......
Page 2: ......
Page 34: ...A 32 ...
Page 46: ...1 4 1 OVERVIEW 1 1 Features ...
Page 60: ...3 6 3 SPECIFICATIONS 3 4 Battery specifications ...
Page 72: ...5 8 5 UL cUL STANDARDS AND EMC DIRECTIVE 5 2 EMC Directive ...
Page 108: ...6 36 6 OPTION 6 7 With wall mounting Attachment ...
Page 124: ...8 10 8 COMMUNICATION CABLE 8 2 External Cable Relay Cable ...
Page 172: ...11 16 11 COMMUNICATION INTERFACE SETTING COMMUNICATION SETTING 11 3 Ethernet Setting ...
Page 200: ...12 28 12 DISPLAY AND OPERATION SETTINGS GOT SET UP 12 6 License Management ...
Page 296: ...14 92 14 FILE DISPLAY AND COPY PROGRAM DATA CONTROL 14 2 Various Data Control ...
Page 320: ...15 24 15 GOT SELF CHECK DEBUG AND SELF CHECK 15 4 GOT start time ...
Page 322: ...16 2 16 CLEANING DISPLAY SECTION CLEAN ...
Page 336: ...17 14 17 INSTALLATION OF COREOS BOOTOS AND STANDARD MONITOR OS 17 5 CoreOS ...
Page 360: ...19 8 19 MAINTENANCE AND INSPECTION 19 5 Backlight Shutoff Detection ...
Page 382: ......
Page 450: ...22 34 22 COMPUTER LINK CONNECTION 22 6 Precautions ...
Page 508: ...23 58 23 ETHERNET CONNECTION 23 5 Precautions ...
Page 526: ......
Page 592: ...26 22 26 SERVO AMPLIFIER CONNECTION 26 7 Precautions ...
Page 598: ...27 6 27 ROBOT CONTROLLER CONNECTION 27 6 Precautions ...
Page 607: ...MULTIPLE GOT CONNECTION FUNCTION 29 MULTIPLE GOT CONNECTION FUNCTION 29 1 ...
Page 608: ......
Page 619: ...MULTI CHANNEL FUNCTION 30 MULTI CHANNEL FUNCTION 30 1 ...
Page 620: ......
Page 635: ...FA TRANSPARENT FUNCTION 31 FA TRANSPARENT FUNCTION 31 1 ...
Page 636: ......
Page 688: ...31 52 31 FA TRANSPARENT FUNCTION 31 7 Precautions ...
Page 698: ...App 10 APPENDICES Appendix 2 Usage Condition of Utility Function ...
Page 703: ......
Page 704: ......
Page 705: ......
Page 706: ......
Page 738: ...A 32 ...
Page 748: ......
Page 820: ...33 44 33 CONNECTION TO OMRON PLC 33 4 Device Range that Can Be Set ...
Page 834: ...34 14 34 CONNECTION TO OMRON TEMPERATURE CONTROLLER 34 7 Precautions ...
Page 912: ...37 22 37 CONNECTION TO JTEKT PLC 37 7 Precautions ...
Page 930: ...38 18 38 CONNECTION TO SHARP PLC 38 6 Device Range that Can Be Set ...
Page 980: ...41 16 41 CONNECTION TO TOSHIBA PLC 41 4 Device Range that Can Be Set ...
Page 996: ...43 8 43 CONNECTION TO PANASONIC SERVO AMPLIFIER 43 7 Precautions ...
Page 1052: ...46 10 46 CONNECTION TO HITACHI PLC 46 6 Device Range that Can Be Set ...
Page 1092: ...47 40 47 CONNECTION TO FUJI PLC 47 5 Precautions ...
Page 1108: ...48 16 48 CONNECTION TO FUJI TEMPERATURE CONTROLLER 48 7 Precautions ...
Page 1142: ...49 34 49 CONNECTION TO YASKAWA PLC 49 4 Device Range that Can Be Set ...
Page 1332: ...55 28 55 CONNECTION TO GE PLC 55 7 Precautions ...
Page 1348: ...56 16 56 CONNECTION TO LS INDUSTRIAL SYSTEMS PLC 56 6 Device Range that Can Be Set ...
Page 1352: ...57 4 57 CONNECTION TO SICK SAFETY CONTROLLER 57 5 Device Range that Can Be Set ...
Page 1368: ...58 16 58 CONNECTION TO SIEMENS PLC 58 4 Device Range that Can Be Set ...
Page 1370: ...59 2 59 CONNECTION TO HIRATA CORPORATION HNC CONTROLLER ...
Page 1372: ...60 2 60 CONNECTION TO MURATEC CONTROLLER ...
Page 1374: ......
Page 1515: ...MODBUS CONNECTIONS 63 MODBUS R RTU CONNECTION 63 1 64 MODBUS R TCP CONNECTION 64 1 ...
Page 1516: ......
Page 1537: ...CONNECTIONS TO PERIPHERAL EQUIPMENT 65 VNC R SERVER CONNECTION 65 1 ...
Page 1538: ......
Page 1545: ......
Page 1546: ......