22 - 30
22. COMPUTER LINK CONNECTION
22.5 PLC Side Setting
22.5.4 Connecting computer link module
POINT
POINT
POINT
Computer link module
For details of the computer link module, refer to the
following manual.
Computer Link Module (Com. link func./Print.
func.) User's Manual
Switch setting on the computer link module
Set the Mode setting switch, the Transmission
specifications switches and the Station number setting
switches.
(1) Mode setting switch
(2) Transmission specifications setting switch
(a) AJ71UC24
• Transmission speed setting (SW13 to SW15)
Set the transmission speed (SW13 to SW15) as
follows.
The transmission speed setting must be consistent
with that of the GOT side.
*1
Only transmission speeds available on the GOT side are
shown.
AJ71UC24
(1)
(3)
(2)
A
J71UC24
2 - C / N
2 - P / S
2 - PRO
2 - SIO
4 - C / N
4 - P / S
4 - PRO
4 - SIO
CPUR / W
COM
M . D . M
M . D . L
B0
B1
B2
L 4
L 5
L 6
RUN
2 - SD
2 - RD
2 - NEU
2 - ACK
2 - NAK
4 - NEU
4 - ACK
4 - NAK
4 - SD
4 - RD
L 1
L 2
L 3
MODE
STATION NO.
10
1
SW11
12
13
14
15
16
17
18
21
22
23
24
O N
RS - 422
RS - 485
SDA
SDB
RDA
RDB
SG
FG
NC
RS-232-C
A1SJ71UC24-R2
NEU
ACK
NAK
C/N
NEU
ACK
NAK
C/N
P/S
PRO
SIO
SIO
SW
03
04
05
06
07
08
09
10
11
12
RS-232-C
A1SJ71UC24-R2
MODE
1.FORM1
2.FORM2
3.FORM3
4.FORM4
5.MOFORM
(1)
(2)
A1SJ71UC24-R2,
A1SJ71UC24-PRF,
A1SJ71C24-R2,
A1SJ71C24-PRF
8
0
23
5
7
8
0
23
5
7
8 9
0
34
B C
D
F
A
1SJ71UC24 - R4
SCAN
SCAN E.
SET E.
SIO E.
ST. DWN
MD / L
NEU
NAK
ACK
C / N
P / S
PRO
SIO
COM
MD
RUN
RD
SD
CPU
SW
01
02
03
04
05
06
07
08
09
10
11
12
10
STATION NO.
1
MODE
SDA
SDB
RDA
RDB
SG
FG
NC
RS - 422 / 485
A1SJ71UC24 - R4
(1)
(3)
(2)
A1SJ71UC24-R4,
A1SJ71C24-R4
PULL
MELSEC A1S
CPU24-R2
STOP
RUN
RESET
RESET
L CLR
RUN
ERROR
STOP
RUN
RESET
RESET
L CLR
RUN
ERROR
MELSEC A1S
CPU24-R2
MITSUBISHI
MITSUBISHI
When the cover is open
When the cover is open
A1SCPUC24-R2
A2CCPUC24, A2CCPUC24-PRF
(1)
(2)
(1)
(3)
(2)
Mode setting switch
Description
Set value
Dedicated
protocol
Format 1
RS-232
connection
1
RS-422
connection
5
Transmission
specifications
setting switch
Setting
switch
Description
Set
value
SW11
Main channel setting
RS-232
connection
OFF
RS-422
connection
ON
SW12
Data bit setting
8bits
ON
SW13
Transmission speed
setting
(Consistent
with the GOT
side
specifications.)
See
descripti
ons
below.
SW14
SW15
SW16
Parity bit setting
Set
ON
SW17
Even/odd parity setting
Odd
OFF
SW18
Stop bit setting
1bit
OFF
SW21
Sum check setting
Set
ON
SW22
Write during RUN
enabled/disabled setting
Enabled
ON
SW23
Computer link/Multidrop
selection
Computer
link
ON
SW24
Master station/Local
station setting
(Setting
ignored)
OFF
Setting switch
Transmission speed
*1
4800bps
9600bps
19200bps
SW13
OFF
ON
OFF
SW14
OFF
OFF
ON
SW15
ON
ON
ON
Summary of Contents for GT14
Page 1: ......
Page 2: ......
Page 34: ...A 32 ...
Page 46: ...1 4 1 OVERVIEW 1 1 Features ...
Page 60: ...3 6 3 SPECIFICATIONS 3 4 Battery specifications ...
Page 72: ...5 8 5 UL cUL STANDARDS AND EMC DIRECTIVE 5 2 EMC Directive ...
Page 108: ...6 36 6 OPTION 6 7 With wall mounting Attachment ...
Page 124: ...8 10 8 COMMUNICATION CABLE 8 2 External Cable Relay Cable ...
Page 172: ...11 16 11 COMMUNICATION INTERFACE SETTING COMMUNICATION SETTING 11 3 Ethernet Setting ...
Page 200: ...12 28 12 DISPLAY AND OPERATION SETTINGS GOT SET UP 12 6 License Management ...
Page 296: ...14 92 14 FILE DISPLAY AND COPY PROGRAM DATA CONTROL 14 2 Various Data Control ...
Page 320: ...15 24 15 GOT SELF CHECK DEBUG AND SELF CHECK 15 4 GOT start time ...
Page 322: ...16 2 16 CLEANING DISPLAY SECTION CLEAN ...
Page 336: ...17 14 17 INSTALLATION OF COREOS BOOTOS AND STANDARD MONITOR OS 17 5 CoreOS ...
Page 360: ...19 8 19 MAINTENANCE AND INSPECTION 19 5 Backlight Shutoff Detection ...
Page 382: ......
Page 450: ...22 34 22 COMPUTER LINK CONNECTION 22 6 Precautions ...
Page 508: ...23 58 23 ETHERNET CONNECTION 23 5 Precautions ...
Page 526: ......
Page 592: ...26 22 26 SERVO AMPLIFIER CONNECTION 26 7 Precautions ...
Page 598: ...27 6 27 ROBOT CONTROLLER CONNECTION 27 6 Precautions ...
Page 607: ...MULTIPLE GOT CONNECTION FUNCTION 29 MULTIPLE GOT CONNECTION FUNCTION 29 1 ...
Page 608: ......
Page 619: ...MULTI CHANNEL FUNCTION 30 MULTI CHANNEL FUNCTION 30 1 ...
Page 620: ......
Page 635: ...FA TRANSPARENT FUNCTION 31 FA TRANSPARENT FUNCTION 31 1 ...
Page 636: ......
Page 688: ...31 52 31 FA TRANSPARENT FUNCTION 31 7 Precautions ...
Page 698: ...App 10 APPENDICES Appendix 2 Usage Condition of Utility Function ...
Page 703: ......
Page 704: ......
Page 705: ......
Page 706: ......
Page 738: ...A 32 ...
Page 748: ......
Page 820: ...33 44 33 CONNECTION TO OMRON PLC 33 4 Device Range that Can Be Set ...
Page 834: ...34 14 34 CONNECTION TO OMRON TEMPERATURE CONTROLLER 34 7 Precautions ...
Page 912: ...37 22 37 CONNECTION TO JTEKT PLC 37 7 Precautions ...
Page 930: ...38 18 38 CONNECTION TO SHARP PLC 38 6 Device Range that Can Be Set ...
Page 980: ...41 16 41 CONNECTION TO TOSHIBA PLC 41 4 Device Range that Can Be Set ...
Page 996: ...43 8 43 CONNECTION TO PANASONIC SERVO AMPLIFIER 43 7 Precautions ...
Page 1052: ...46 10 46 CONNECTION TO HITACHI PLC 46 6 Device Range that Can Be Set ...
Page 1092: ...47 40 47 CONNECTION TO FUJI PLC 47 5 Precautions ...
Page 1108: ...48 16 48 CONNECTION TO FUJI TEMPERATURE CONTROLLER 48 7 Precautions ...
Page 1142: ...49 34 49 CONNECTION TO YASKAWA PLC 49 4 Device Range that Can Be Set ...
Page 1332: ...55 28 55 CONNECTION TO GE PLC 55 7 Precautions ...
Page 1348: ...56 16 56 CONNECTION TO LS INDUSTRIAL SYSTEMS PLC 56 6 Device Range that Can Be Set ...
Page 1352: ...57 4 57 CONNECTION TO SICK SAFETY CONTROLLER 57 5 Device Range that Can Be Set ...
Page 1368: ...58 16 58 CONNECTION TO SIEMENS PLC 58 4 Device Range that Can Be Set ...
Page 1370: ...59 2 59 CONNECTION TO HIRATA CORPORATION HNC CONTROLLER ...
Page 1372: ...60 2 60 CONNECTION TO MURATEC CONTROLLER ...
Page 1374: ......
Page 1515: ...MODBUS CONNECTIONS 63 MODBUS R RTU CONNECTION 63 1 64 MODBUS R TCP CONNECTION 64 1 ...
Page 1516: ......
Page 1537: ...CONNECTIONS TO PERIPHERAL EQUIPMENT 65 VNC R SERVER CONNECTION 65 1 ...
Page 1538: ......
Page 1545: ......
Page 1546: ......