background image

Interflex Datensysteme GmbH   

1/8 

 

 

1  IF-810 or IF-811 Terminal (Slave) 

Thank you for choosing an Interflex system. With an IF-810 or 
IF-811 terminal (slave), you have purchased a reliable device for 
capturing access data. 

 

Furthermore, with an IF-811 terminal (slave), you can also enter 
your PIN via a membrane keypad. 

 

Scope of delivery:   

 

IF-810 or IF-811 terminal (slave) 

 

Terminal strip board 

 

Mortise lock 

 

Material for wall mounting 

 

  Please check the completeness and condition of the shipment 

upon receipt. 

 

 

 

2  Intended Use 

Slave terminals of the IF-810/IF-811 series are devices for capturing access data as well as for writing to 
RFID credentials. Furthermore, with an IF-811 terminal (slave), you can also enter your PIN. The device is 
designed for indoor and outdoor use (see note). Any other use is not in accordance with the intended 
purpose and is therefore not permitted. 

 

3  Assembly and Installation 

 

 

95-10326_V2016-10-20 IF-810/IF-811 

 

 

Summary of Contents for IF-810

Page 1: ...erminal strip board Mortise lock Material for wall mounting Please check the completeness and condition of the shipment upon receipt 2 Intended Use Slave terminals of the IF 810 IF 811 series are devices for capturing access data as well as for writing to RFID credentials Furthermore with an IF 811 terminal slave you can also enter your PIN The device is designed for indoor and outdoor use see not...

Page 2: ...e slave terminal and other systems with RFID readers keeping a distance of 10 cm between connecting cables and power lines The following installation procedure has been proven and tested 1 Install the cables 2 Install the power supply 3 Mount the back panel of the IF 810 IF 811 If the terminal is to be used for access control an I O controller board must also be mounted in a secured area 4 Set the...

Page 3: ...pen 1 Unlock the mortise lock and pull it down and out 2 Insert the pins of the tool 2 into the housing from the bottom and by doing so push open the two internal latches 3 With the latches unlocked swivel up the housing cover 4 Disconnect the connecting cable and remove the housing cover Close 1 Plug in the connecting cable at the respective board 2 Tilt the housing cover and hook it onto the upp...

Page 4: ...erminal slave can be installed in dry or humid environments IP43 Installation is performed on flat walls or pillars e g next to doors using the materials included in delivery The I O board is installed in a secured area e g into an installation box from Hensel or a DIN appliance case The sealant 4 used evens out unevenness in the wall and makes a seal to the wall This sealant allows for installati...

Page 5: ...ster terminal Address 2 OFF OFF OFF ON Address 3 OFF OFF ON OFF Address 4 OFF OFF ON ON Address 5 OFF ON OFF OFF Address 6 OFF ON OFF ON Address 7 OFF ON ON OFF Address 8 OFF ON ON ON 3 6 Wiring Power supply Power can be supplied via a 12 VAC 24 VAC power transformer via a 12 VAC 24 VAC low voltage power supply unit via an IF 79 I O BUS panel max 100 m Connecting the BUS cable The IF 810 IF 811 te...

Page 6: ...ell as to terminal 4 or 10 on the I O controller board 3 7 Controlling Locking Devices with I O Controller Board 1 I O controller board accessories 2 Power supply connection 1a Br 4 jumper selection 3 Data cable connection 1b Br 1 relay contact in NO or NC position 4 Connection of electric control element door opener 1d Br 5 plug contact for anti tamper switch 5 Connection of door sensor handle or...

Page 7: ... 4 An actuator shown as a door opener in the figure is connected to terminals 8 and 9 The actuator is controlled by the relay of the I O controller board and can switch a maximum of 30 V and 2 A Via the bridge 1b the relay contact can be changed from normally open NO to normally closed NC If two relay outputs are required a further I O controller board is needed Connection of sensors 5 Two sensors...

Page 8: ...us bar with LEDs blue green red Data entry As opposed to IF 811 the IF 810 terminal is not equipped with a keypad The IF 811 terminal is equipped with a numeric membrane keypad Device Protection Protection category III Degree of protection IP43 IP54 after sealing the mortise lock General Data Ambient temperature 25 C to 55 C Humidity Max 95 non condensing Product safety EN 60950 1 Compatibility EM...