Parameter list with instruction codes
Appendix
A - 14
Function
Para-
meter
Instruction Code
Name
Control Mode-based
Correspondence Table
Refer
to Page
Customer
Setting
Read
Write
Extended
V/f Control
General-
Purpose
magnetic
Flux Vector
Control
PU connector
communication
117
11
91
1
PU communication station number
✔
✔
118
12
92
1
PU communication speed
✔
✔
119
13
93
1
PU communication stop bit length
✔
✔
120
14
94
1
PU communication parity check
✔
✔
121
15
95
1
Number of PU communication retries
✔
✔
122
16
96
1
PU communication check time interval
✔
✔
123
17
97
1
PU communication waiting time setting
✔
✔
124
18
98
1
PU communication CR/LF selection
✔
✔
—
125
19
99
1
Terminal 2 frequency setting gain frequency
✔
✔
—
126
1A
9A
1
Terminal 4 frequency setting gain frequency
✔
✔
PID control
127
1B
9B
1
PID control automatic switchover frequency
✔
✔
128
1C
9C
1
PID action selection
✔
✔
129
1D
9D
1
PID proportional band
✔
✔
130
1E
9E
1
PID integral time
✔
✔
131
1F
9F
1
PID upper limit
✔
✔
132
20
A0
1
PID lower limit
✔
✔
133
21
A1
1
PID action set point
✔
✔
134
22
A2
1
PID differential time
✔
✔
PU
145
2D
AD
1
PU display language selection
✔
✔
—
146
Parameter for manufacturer setting. Do not set.
Current
detection
150
32
B2
1
Output current detection level
✔
✔
151
33
B3
1
Output current detection signal delay time
✔
✔
152
34
B4
1
Zero current detection level
✔
✔
153
35
B5
1
Zero current detection time
✔
✔
—
156
38
B8
1
Stall prevention operation selection
✔
✔
—
157
39
B9
1
OL signal output timer
✔
✔
Display
selection
158
3A
BA
1
AM terminal function selection
✔
✔
—
160
00
80
2
Extended function display selection
✔
✔
—
161
01
81
2
Frequency setting/key lock operation selection
✔
✔
Automatic
restart functions
162
02
82
2
Automatic restart after instantaneous power
failure selection
✔
✔
165
05
85
2
Stall prevention operation level for restart
✔
✔
Current
detection
166
06
86
2
Output current detection signal retention time
✔
✔
167
07
87
2
Output current detection operation selection
✔
✔
—
168
Parameter for manufacturer setting. Do not set.
—
169
Tab. A-5:
Parameter list with instruction codes (4)
Summary of Contents for FR-D720S SC EC
Page 2: ......
Page 4: ......
Page 24: ...Description of the case Product checking and part identification 1 4 ...
Page 108: ...Operation panel Operation 4 20 ...
Page 436: ...Setting for the parameter unit and operation panel Parameter 6 286 ...
Page 484: ...Measurements on the main circuit Maintenance and inspection 8 14 ...
Page 504: ...Specification change Appendix A 20 ...
Page 505: ......
Page 506: ......
Page 510: ...Index Appendix A 24 ...
Page 511: ......