Basic settings
External operation
FR-D700 SC EC
5 - 31
5.3 External
operation
When operating the inverter via external signals, the motor is started and stopped by external
signals connected to terminals STF and STR of the inverter. Just as when operating using the
parameter unit, the set frequency value may originate from various sources:
●
A fixed set value
Operation at the frequency set in the frequency setting mode of the PU. (Refer to section
5.3.1.)
●
Selection of stored set values by external signals
Give a frequency command by switch (multi-speed setting). (Refer to section 5.3.2).
●
Setpoint setting made by external analog signals
Perform frequency setting by a voltage output device (section 5.3.3.) or by a current output
device (section 5.3.4).
5.3.1
Use the set frequency set by PU (Pr. 79 = 3)
●
Set "3" in Pr. 79 (External/PU combined operation mode 1).
●
Switch terminal STF (STR)-PC on to give a start command.
●
Refer to section 5.2.1 for the set frequency by PU.
I002027E
Fig. 5-20:
External operation
Power supply
Motor
Inverter
Forward rotation start
Reverse rotation start
Set frequency
Operation
panel
Summary of Contents for FR-D720S SC EC
Page 2: ......
Page 4: ......
Page 24: ...Description of the case Product checking and part identification 1 4 ...
Page 108: ...Operation panel Operation 4 20 ...
Page 436: ...Setting for the parameter unit and operation panel Parameter 6 286 ...
Page 484: ...Measurements on the main circuit Maintenance and inspection 8 14 ...
Page 504: ...Specification change Appendix A 20 ...
Page 505: ......
Page 506: ......
Page 510: ...Index Appendix A 24 ...
Page 511: ......