Parameter overview
Parameter
6 - 4
Func-
tion
Parameter
Name
Incre-
ments
Initial
value
Setting
range
Description
Para-
meter
copy
Para-
meter
clear
All
Para-
meter
clear
Refer
to
page
Rel
a
ted
pa
ramet
e
rs
✔
: enabled
—: disabled
MRS input
selection
17
MRS input selection
1
0
0
Open input always
✔
✔
✔
2
Normally closed input (NC contact
input specifications)
4
External terminal: Normally closed
input (NC contact input specifica-
tions)
Communication: Normally open
input
—
18
Refer to Pr. 1 and Pr. 2
19
Refer to Pr. 3
20
Refer to Pr. 7 and Pr. 8
Stall prevention operation
22
Stall prevention
operation level
0.1%
150%
0
Stall prevention operation
selection becomes invalid.
✔
✔
✔
0.1–200%
The stall prevention operation level
can be set.
23
Stall prevention opera-
tion level compensa-
tion factor at double
speed
0.1%
9999
0–200%
The stall operation level can be
reduced when operating at a high
speed above the rated frequency.
✔
✔
✔
9999
Constant according to Pr. 22
48
Second stall prevention
operation current
0.1%
9999
0
Second stall prevention operation
invalid
✔
✔
✔
0–200%
The stall prevention operation level
can be set.
9999
Same level as Pr. 22.
66
Stall prevention opera-
tion reduction starting
frequency
0.01Hz
50Hz
0–400Hz
Set the frequency at which the stall
operation level is started to
reduce.
✔
✔
✔
156
Stall prevention
operation selection
1
0
0–31/100/
101
Pr. 156 allows you to select
whether to use stall prevention or
not according to the acceleration/
deceleration status.
✔
✔
✔
157
OL signal output timer
0.1s
0s
0–25s
Set the output start time of the OL
signal output when stall preven-
tion is activated.
✔
✔
✔
9999
Without the OL signal output
—
24
–
27
Refer to Pr. 4 to Pr. 6
Acceleration/
deceleration pattern
29
Acceleration/decelera-
tion pattern selection
1
0
0
Linear acceleration/deceleration
✔
✔
✔
1
S-pattern acceleration/
deceleration A
2
S-pattern acceleration/
deceleration B
Selection of regeneration unit
30
Regenerative function
selection
1
0
0
Brake unit FR-BU2, High power
factor converter FR-HC, Power
regeneration common converter
FR-CV
✔
✔
✔
1
High-duty brake resistor FR-ABR
2
High power factor converter
FR-HC (when an automatic restart
after instantaneous power failure
is selected)
70
Special regenerative
brake duty
0.1%
0%
0–30%
Set this parameter when a high
duty brake resistor or power
regeneration converter is used.
✔
✔
✔
Tab. 6-1:
Parameter overview (4)
Summary of Contents for FR-D720S SC EC
Page 2: ......
Page 4: ......
Page 24: ...Description of the case Product checking and part identification 1 4 ...
Page 108: ...Operation panel Operation 4 20 ...
Page 436: ...Setting for the parameter unit and operation panel Parameter 6 286 ...
Page 484: ...Measurements on the main circuit Maintenance and inspection 8 14 ...
Page 504: ...Specification change Appendix A 20 ...
Page 505: ......
Page 506: ......
Page 510: ...Index Appendix A 24 ...
Page 511: ......