Operation panel
Operation
4 - 12
Possible faults:
●
"Er1" ("Write disable error") is displayed
– Parameter write is disabled with "1" set in Pr. 77.
●
"Er2" is displayed
– Setting can not be made during operation. Stop the motor with the STOP/RESET key or
by switching off the STR/STF signal.
●
The priorities of the frequency commands when Pr. 79 = "3" are: "Multi-speed operation
(RL/RM/RH/REX) > PID control (X14) > terminal 4 analog input (AU) > digital input from the
operation panel".
Operation Mode
Operation Panel Indication
Operation Method
Start Command
Frequency Command
PU Modes
External operation mode
External
(STF-, STR)
External
(Analog signal at
terminal 2 (voltage) or
4 (current))
Combined operation
mode 1
External
(STF-, STR)
Combined operation
mode 2
External
(Analog signal at
terminal 2 (voltage) or
4 (current))
Tab. 4-4:
Operation modes and operation panel indication
Flickering
Flickering
Flickering
Flickering
Flickering
Flickering
Flickering
Flickering
Summary of Contents for FR-D720S SC EC
Page 2: ......
Page 4: ......
Page 24: ...Description of the case Product checking and part identification 1 4 ...
Page 108: ...Operation panel Operation 4 20 ...
Page 436: ...Setting for the parameter unit and operation panel Parameter 6 286 ...
Page 484: ...Measurements on the main circuit Maintenance and inspection 8 14 ...
Page 504: ...Specification change Appendix A 20 ...
Page 505: ......
Page 506: ......
Page 510: ...Index Appendix A 24 ...
Page 511: ......