5 ERROR lag logic
The logic of the error output is selectable from [Negative logic] or [Positive logic].
[Negative logic] is set as default.
6 P.C. (print command) Logic
The logic of P.C. output is selectable from [Negative logic] or [Positive logic].
[Negative logic] is set as default.
7
P.C. (print command) width
The data width of P.C. output is selectable from [125 ms], [25 ms] or [5 ms].
[125 ms] is set as default.
8 BCD output times
The numbers of BCD output times is selectable from [100 times/s], [20 times/s] or
[4 times/s].
[4 times/s] is set as default.
Note:
-
Before and after starting up the print command, BCD output becomes unstable due
to the conversion of BCD data.
-
Please read the correct BCD data at the timing of the falling of the print command.
-
The internal circuit is insulated with optocoupler.
17.2.4
Pin assignment of the BCD output
The BCD output are divided into two with the setting of [Output target].
At the time of setting load display, gross weight, net weight and tare weight
A1
1 x 10
0
B1
2 x 10
0
A2
4 x 10
0
B2
8 x 10
0
A3
1 x 10
1
B3
2 x 10
1
A4
4 x 10
1
B4
8 x 10
1
A5
1 x 10
2
B5
2 x 10
2
A6
4 x 10
2
B6
8 x 10
2
A7
1 x 10
3
B7
2 x 10
3
A8
4 x 10
3
B8
8 x 10
3
A9
1 x 10
4
B9
2 x 10
4
A10
4 x 10
4
B10
8 x 10
4
A11
1 x 10
5
B11
2 x 10
5
A12
4 x 10
5
B12
8 x 10
5
A13
ERROR
B13
N. C.
Weight Controller CSD-918
17 Options