Note:
-
Conirm the setting (refer to Chapter
) before moving the gate by manual
operation. According to the set value, there is a possibility of movement diferent
from the direction that the gate intended.
-
Calibrate at the speed that can be operated by the manual operation.
7.6 Positional calibration (POSITION CALIB.)
A positional calibration is executed after selecting each calibration method of original
point positional calibration from TYPE1, TYPE2 or TYPE3, and full open positional
calibration from TYPE1 or TYPE2 respectively.
Calibration method of original point
Type
Original point
sensor
Limit sensor for
OPEN side and
CLOSE side
Remarks
TYPE1 –
–
Gate is moved by manual operation. Ori-
ginal point position is conirmed by sight.
The original point position is set.
TYPE2
◯
–
Gate is moved by manual operation. Ori-
ginal point position is detected by origi-
nal point sensor. The original point positi-
on is set.
TYPE3
◯
◯
When the operator selects [START], the
gate moves by automatic operation. Ori-
ginal point position is detected by origi-
nal point sensor. The original point positi-
on is set.
Calibration method of full open position
Type
Remarks
TYPE1
Gate is moved by manual operation. Full open point position is conir-
med by sight. The full open point position is set.
TYPE2
The full open point position is set by inputting the servo motor rotati-
on value or input pulse.
1. Select [HIGH SPEED CALIB.] in the screen of manual speed calibration.
2. Select [HIGH SPEED] at high speed calibration screen.
3. Input rotation value (min
-1
) of the servo motor in high speed movement with ten key.
4. Tap [OK].
5. Tap [OPEN] or [CLOSE], and conirm the speed of the gate in the movement of gate
OPEN or gate CLOSE.
6. Tap [OK].
7 Servo calibration
Weight Controller CSD-918
Minebea Intec
EN-63