Error code Error
No.
Contents
Measures
SQERR 9
:
The measurement begins in the condition that
[START ABOVE ZERO BAND] is [EFFECTIVE], ho-
wever the container is not put on the weighing
section.
Check whether the container is put.
SQ.ERR 10 ;
When you input the weighing signal while the ga-
te is operated with manual.
Conirm if this unit is in weighing mo-
de.
SQ.ERR 11
<
When the weighing signal is input excluding the
original point position of gate
Conirm the position of the gate.
Note:
Tap [ERR.RESET] on top left corner of the display to cancel the sequence error.
19.2.4 Error alarm buzzer
When key lock is active, tapping any key sounds a buzzer twice.
Note:
Refer to Chapter
for more information.
19.3 Display of servo error
Error code
Error No. Cause
Action
SV.ERR EMG
1
The emergency stop is detected.
Turn on the power again after conirming
the cause that the emergency stop detec-
ted.
SV.ERR ALM
2
The servo alarm signal is output from
the servo ampliier.
Turn on the power again after conirming
the servo ampliier and the servo motor.
SV.ERR RD
3
The ready signal is not output from
the servo ampliier.
Conirm the servo ampliier and the servo
motor.
SV.ERR +LMT
4
The gate is exceeding the OPEN side
limit position.
Move it to the right position after conir-
ming the position of the gate.
SV.ERR -LMT
5
The gate is exceeding the CLOSE side
limit position.
Move it to the right position after conir-
ming the position of the gate.
SV.ERR SLMT
6
The gate is exceeding the software li-
mit position.
Move it to the right position after conir-
ming the position of the gate.
SV.ERR ORG
7
The original point cannot be detected
by the power on original point detec-
tion.
Detect the original point by a position cali-
bration after conirming the position of the
gate.
Weight Controller CSD-918
19 Troubleshooting
EN-202
Minebea Intec
Summary of Contents for CSD-918 Series