When the value of automatic Free Fall efective width is 0, an Automatic Free Fall
calculation will not be operated.
The Automatic Free Fall compensationrrection is cleared when the change of set value or
the BRAND number has changed, or at the time of turning of the power supply.
11.6.6
Input of SAFETY CONFIRMATION
The input of safety conirmation is a function to stop the measurement sequence
automatically when abnormality is occurred such as the hopper used is fallen down and
the vessel for the measurment is not prepared.
[Safety conirmation input 1 to 8] allocated to exeternal control input function. (CONTROL
I/O) is used for the input of safety conirmation.
Refer to Chapter
for the setting method of Safety conirmation. The safety
conirmation input is registered up to 8 items.
The input used is speciied by setting the safety conirmation condition.
Turn on each safety conirmation of [BATCHING SAFETY CHECK], [DISCH. SAFETY CHECK]
and [GENERAL SAFETY CHECK] (refer to Chapter
Load cell
Safety confirmation input
In case of no container, etc.
Weighing hopper
Coarse / Middle / Fine flow
Batch gate
Sequence error output
SQ.ERR1
Container detection switch
11.6.7
MIXING mode
The MIXING mode is to be used for control the motor that works to mix the object to be
measured.
The MIXING signal is output from the connector pin set to [MIX] by the external control I/
O.
The output timing of MIX signal (start mixing) can be set to each of [BATCH FINISH],
[DISCHARGE FINISH] and [MIXING FINISH] (Plurals can be selected), refer to
Chapter
.
[MIXING TIME OUTPUT ON] is to set the output time of MIXING signal .
[MIXING FINISH OUTPUT ON] is to set the output time of MIXING inish signal .
Refer to Chapter
11 Weighing mode
Weight Controller CSD-918
Minebea Intec