OPERATION OF TA-
RE
DECIMAL POINT
RANGE OF TARE
UNIT
ZERO AT POWER ON BRIDGE POWER
SUPPLY
ZERO CLR.AT POW-
ER ON
OL DISPLAY CONDI-
TION
TARE AT POWER ON ADJ.GRAV.ACCELERATION
TARE CLR.AT POW-
ER ON
CALIB. PLACE No.
OPERATION OF STA-
BILITY
OPERATION PLACE
No.
CALIB. PLACE G.A.
OPERATION PLACE
G.A.
FINE ADJUSTMENT
DIGITAL LINEARISE
PITCH CONFIRMATI-
ON SET
PITCH CONFIRMATI-
ON
6.8 Various functions set by the other calibration screen
6.8.1
Position of decimal point (DECIMAL POINT)
The decimal point is selectable from [0], [0.0], [0.00], [0.000] or [0.0000].
[0] is selected as default.
6.8.2
Display condition of OL (OL DISPLAY CONDITION)
The display condition of over is selectable from [+ 9D], [±110 %] or [-20D ~ 9D].
[+ 9D] is selected as default.
6.8.3
Unit (UNIT)
The unit is selectable from [no display], [g], [kg], [t], [lb], [N] or [kN].
[no display] is selected as default.
6.8.4
Compensation of gravitational acceleration
When the calibration place of scale is diferent from its using place, an error at span is
caused due to the gravitational acceleration of each district.
The compensation function of gravitational acceleration corrects the span error by setting
the two district number or the two gravitational acceleration number between the
calibration place and its using place.
If the calibration place and its using place is the same, the compensation of gravitational
acceleration is not required.