20 Discharge inish output on (DISCH. FINISH OUTPUT ON)
The output time for the Discharge inish signal is set.
This time is input with ten-keys in the range from 0.01 to 99.99 in every [0.01] se-
cond, and this function becomes of when [0.00] is set.
[0.00] is set as default.
21 Mixing inish output on (MIXING FINISH OUTPUT ON)
The output time for the Mixing inish signal is set.
This time is input with ten keys in the range from [0.01] to [99.99] in every [0.01]se-
cond, and this function becomes of when [0.00] is set.
[0.00] is set as default.
22 Mixing time output on (MIXING TIME OUTPUT ON)
The output time for the Mixing signal is set.
This time is input with ten keys in the range from 0 to 9 999 in every [1] second, and
this function becomes of when [0] is set.
[0] is set as default.
Weight Controller CSD-918
11 Weighing mode
EN-126
Minebea Intec
Summary of Contents for CSD-918 Series