Item name
Command name
Com-
mand
Number Return command setting value
Open rate
AL
04
0.000 to 100.000 % (Unit: 0.001 %)
FIXED OPEN (WEIGHT)
Weight
AM
02
999 999
Open rate
AM
04
0.000 to 100.000 % (Unit: 0.001 %)
FIXED OPEN (WEIGHT)
Weight
AN
02
999 999
Fine low
Open rate
AN
04
0.000 to 100.000 % (Unit: 0.001 %)
Note:
-
The command number during writing changes from [72], as described in the table,
to [82].
-
The command number during writing changes from [73], as described in the table,
to [83].
-
The command number during writing changes from [74], as described in the table,
to [84].
-
The command number during writing changes from [75], as described in the table,
to [85].
-
Set the SPAN calibration such that [WEIGHING CAPACITY (maximum load) ≥ SPAN
ADJUSTMENT (calibration)]
-
The same command can be used if this unit is installed in a system that has already
used four digits after the decimal point to register ZERO point (No.06) and SPAN
point (No.07) as mV/V.
-
Note the mistake in the set digit number if the command is changed to ive digits
after the decimal point to register ZERO point (No.26) and SPAN point (No.27) as
mV/V.
-
The command number during writing changes from [A0],[A5]and[A6,]as described
in the above table, to [B0],[B5]and[B6].
-
The command number during writing changes from [AP], [AA], [AC], [AD], [AE]and
[AF,]as described in the above table, to [BP], [BA], [BC],[BD], [BE]and [BF].
-
The command number during writing changes from [AF], [AG]and[AH,]as described
in the above table, to [BF], [BG]and [BH].
-
The command number during writing changes from [AH], [AI], [AJ], [AK], [AM]and
[AN,]as described in the above table, to [BH], [BI], [BJ], [BK], [BM]and [BN].