14 Accumulation times (ACCUM.TIMES)
This function is used in the conirmation and the clear of the accumulation times of
an efective brand.
When the accumulation times is cleared, the accumulation value of an efective
brand is also cleared.
15 Preset tare value (PRESET TARE)
When preset tare cancellation is applied, the tare weight cancellation value is set.
The setting range is from [0 to 999 999], and input in every [1] with ten keys.
[0] is set as default.
Refer to Chapter
.
11.2 Coarse low (FULL FLOW)
The control method of gate at full low is set.
The control method is selectable from [FIXED OPEN (TIME)] or [FIXED OPEN (WEIGHT)].
The open rate and the completing time of full low are set for [FIXED OPEN (TIME)]. The
open rate and the weight are set for [FIXED OPEN (WEIGHT)].
[FIXED OPEN (TIME)] is set as default.
11.2.1
Switch to coarse low screen
The screen is switched from weighing screen to coarse low screen by the following
operation.
11.2.2
Coarse low ixed open rate (time)
The open rate of the gate in coarse low and the completing time of coarse low are set.
The open rate is a relative value to the full open position at the gate.
The setting range of open rate of the gate is from [0.000 %] to [100.000 %] and the
setting range of the completing time of coarse low is from [50 ms] to [10 000 ms].
[50.000 %] is set as default for open rate of the gate, and [50 ms] for the completing time
of coarse low.
O
pen
rat
e[
%]
Time[ms]
1. Select [MENU].
2. Select [BRAND CODE] in menu screen 1/2.
3. Select [FULL FLOW] in brand code screen 1/2.
Weight Controller CSD-918
11 Weighing mode
EN-98
Minebea Intec