Item name
Command name
Com-
mand
Number Return command setting value
Deviation software limit
setting
A5
09
1.000 to 100.000 % (Unit: 0.001 %)
Alarm signal
A6
01
2: [BRIDGE]; 3:[OPEN]
OPEN side limit signal
A6
02
1: [OFF]; 2: [BRIDGE]; 3: [OPEN]
CLOSE side limit signal
A6
03
1: [OFF]; 2: [BRIDGE]; 3: [OPEN]
Original point sensor sig-
nal
A6
04
1: [OFF]; 2: [BRIDGE]; 3: [OPEN]
Ready signal
A6
05
2: [BRIDGE]; 3: [OPEN]
PREVENT SCATTER
AP
01
1: [OFF]; 2: [ARBITRARY]; 3: [QUADRATIC
EQUATION]
QUADRATIC EQUATION
setting
AB
01
100 ~ 10,000 ms (Unit: ms)
ARBITRARY
Number of points
AA
98
1 to 3
Point1 time
AA
01
50 to 10 000 ms (Unit: ms)
Point1 open rate
AA
04
0.000 to 100.000 % (Unit: 0.001 %)
Point2 time
AA
11
50 to 10 000 ms (Unit: ms)
Point2 open rate
AA
14
0.000 to 100.000 % (Unit: 0.001 %)
Point3 time
AA
21
50 to 10 000 ms (Unit: ms)
PREVENT
SCATTER
Point3 open rate
AA
24
0.000 to 100.000 % (Unit: 0.001 %)
Coarse low
AP
02
1:[FIXED OPEN (TIME)]; 2:[FIXED OPEN
(WEIGHT)]
FIXED OPEN (TIME)
Time
AC
01
50 to 10 000 ms (Unit: ms)
Open rate
AC
04
0.000 to 100.000 % (Unit: 0.001 %)
FIXED OPEN (WEIGHT)
Weight
AD
02
999 999
Coarse low
Open rate
AD
04
0.000 to 100.000 % (Unit: 0.001 %)
Middle low
AP
03
1: [FIXED OPEN (TIME)]; 2: [FIXED OPEN
(WEIGHT)]; 3: [ARBITRARY]; 4: [QUADRATIC
EQUATION]
ARBITRARY
Number of points
AE
98
1 to 50
Point1 time
AE
01
50 to 10 000 ms (Unit: ms)
Point1 open rate
AE
04
0.000 to 100.000 % (Unit: 0.001 %)
Middle low
Point2 time
AE
11
50 to 10 000 ms (Unit: ms)
17 Options