Item name
Command name
Com-
mand
Number Return command setting value
SAFETY CHECK 1
73
51
1: [ON]; 2: [OFF]
SAFETY CHECK 2
73
52
1: [ON]; 2: [OFF]
SAFETY CHECK 3
73
53
1: [ON]; 2: [OFF]
SAFETY CHECK 4
73
54
1: [ON]; 2: [OFF]
SAFETY CHECK 5
73
55
1: [ON]; 2: [OFF]
SAFETY CHECK 6
73
56
1: [ON]; 2: [OFF]
SAFETY CHECK 7
73
57
1: [ON]; 2: [OFF]
SAFETY CHECK 8
73
58
1: [ON]; 2: [OFF]
AUTOMATIC ACCUM.
73
61
1: OFF; 2: SYNC WITH FINISH; 3: AUTO AC-
CUM AT STABLE
CONDITION OF AUTO
ACM.
73
62
1: OK OPERATION; 2: Unconditional
AUTOMATIC PRINT
73
64
1: EFFECTIVE; 2: INVALID
Signal operation of INFLOW start
START ABOVE ZERO
BAND
74
01
1: EFFECTIVE; 2: INVALID
AUTOMATIC TARE
WEIGHT
74
02
1: EFFECTIVE; 2: INVALID
NOZZLE OPERATION
NOZZLE CONTROL
74
03
1: EFFECTIVE; 2: INVALID
CONTACT STOP SEQUEN-
CE
74
04
1: EFFECTIVE; 2: INVALID
UP AFTER COMPENSATI-
ON
74
05
1: EFFECTIVE; 2: INVALID
JUDGMENT CONDITION
74
06
1: After calming time (waiting time); 2: After
calming time (waiting time) and stabilizati-
on; 3: After calming time (waiting time) or
stabilization
Operation when measurement is complete (INFLOW FINISH ACTIONS)
MIXING START
74
07
1: EFFECTIVE; 2: INVALID
DISCHARGE START
74
08
1: EFFECTIVE; 2: INVALID
Operation when discharge is complete (DISCHARGE FINISH ACTIONS)
TARE WEIGHT CLEAR
74
09
1: EFFECTIVE; 2: INVALID
MIXING START
74
10
1: EFFECTIVE; 2: INVALID
Sequence con-
trol setting
MAXTIME OF COMPENSA-
TION
74
15
0 to 255 times; 0: Turn of (Unit: times)
Weight Controller CSD-918
17 Options
EN-174
Minebea Intec
Summary of Contents for CSD-918 Series
Page 239: ......