11.4.1
Switch to ine low screen
The screen is switched from weighing screen to ine low screen by the following
operation.
11.4.2
Fine low ixed open rate (weight)
The open rate in the ine low and the weight are set.
The open rate is a relative value to the full low position at the gate.
The setting range of open rate of the gate is from [0.000 %] to [100.000 %] and the
setting range of the weight is from [0] to [999 999].
[10.000 %] for open rate of the gate, and [100] for the weight is set as default.
O
pen
rat
e
[%]
Time [ms]
W
eighing
Time [ms]
Middle Flow Fine Flow
Full Flow
Middle Flow FineFlow
Full Flow
Note:
-
The open rate is a relative value to the full open position at the gate.
-
In this control method, the gate reaches the open rate set before at once, and is
maintained until the weight set before.
1. Select [MENU].
2. Select [BRAND CODE] in menu screen 1/2.
3. Select [DRIBBLE FLOW] in brand code screen 1/2.
1. Select [FIXED OPEN (WEIGHT)] in the ine low screen.
2. Select [WEIGHT], and input the weight value that reaches in ine low with ten keys,
and then tap [OK].
3. Select [OPEN], and input the open rate of the gate with ten keys, and then tap [OK].