Code Type Commands
MS-810 Industrial Scanner User’s Manual
3-13
3–Ser
ial
Conf
ig.
Code Type Commands
Code 39
Format: <
Kp
status,check digit status,check digit output status,large intercharacter
gap,fixed code length status,code length>
Example: To set Fixed Code Length to 30, send
<K,,,,1,30>
or
<Kp1,0,0,0,1,30>
.
Codabar
Format: <
Kq
status,start & stop match status,start & stop output status,large
intercharacter gap,fixed code length status,code length,check digit type,check digit
output>
Example: To set Fixed Code Length to 9, send
<Kq1,,,,1,9>
or
<Kq1,1,1,0,1,9>
.
I 2 of 5
Format: <
Kr
status,check digit status,check digit output status,code length #1,code
status:
0 = Disabled
1 = Enabled
check digit status:
0 = Disabled
1 = Enabled
check digit output status:
0 = Disabled
1 = Enabled
large inter-character gap:
0 = Disabled
1 = Enabled
fixed code length
status:
0 = Disabled
1 = Enabled
code length:
Default is
10
.
Any number from 1 to
64.
status:
0 = Disabled
1 = Enabled
start & stop match status:
0 = Disabled
1 = Enabled
start & stop output status:
0 = Disabled
1 = Enabled
l
arge inter-character gap:
0 = Disabled
1 = Enabled
fixed code length status:
0 = Disabled
1 = Enabled
code length:
Default is
10
Any number from 1 to 64.
check digit type:
0 = Disabled
1 = Mod 16
2 = NW7
3 = Both
check digit output:
0 = Disabled
1 = Enabled
Summary of Contents for MS-810
Page 1: ...MS 810 Industrial Scanner User s Manual P N 83 000810 Rev B...
Page 22: ...Chapter 1 1 12 MS 810 Industrial Scanner User s Manual 1 Quick Start...
Page 82: ...Chapter 3 3 20 MS 810 Industrial Scanner User s Manual 3 Serial Config...
Page 98: ...Chapter 4 4 16 MS 810 Industrial Scanner User s Manual 4 Utilities...
Page 138: ...Chapter A A 40 MS 810 Industrial Scanner User s Manual Appendices...
Page 144: ...I 6 MS 810 Industrial Scanner User s Manual Index Index...