Operation Commands
MS-810 Industrial Scanner User’s Manual
3-11
3–Ser
ial
Conf
ig.
External Trigger Level
Format: <
Kj
external trigger level>
Example: To change External Trigger Level to Negative, send
<Kj0>
.
Good Decode Reads
Format: <
Km
number of reads>
Example: To change Good Decode Reads to 3, send
<Km3>
.
Match Code Type
Format: <
Kn
type,sequential matching,match start position,match length,wild card
character,sequence on noread,sequence on every mismatch>
external trigger level (initiates a read cycle):
0 = Negative
1 = Positive
number of reads (before a good decode):
Default is
1
.
Any number from 1 to 31.
type:
0 = Disabled
1 = Enabled
2 = Wild Card
3 = Sequential
sequential matching
0 = Increment
1 = Decrement
match start position
Default is
0
.
0 to 64
match length
Default is
1
.
1 to 31
wild card character
Default is
*
.
Any ASCII character.
sequence on noread:
0 = Disabled
1 = Enabled
When enabled, the scanner sequences (increment or dec-
rement) on every noread.
If 001, 002, noread, then
search for 003.
If 001, 002, noread, then
search for 004.
sequence on every mismatch:
0 = Disabled
1 = Enabled
When disabled, if a mismatch is out of sequence by no
more than 1, then the sequence resumes and searches
indefinitely.
When enabled, the scanner sequences on every mis-
match.
If 001, 002,
004 (mismatch), then
search for 005.
If 001, 002, mismatch,
then search for 004. If mis-
match occurs again, then
search for 005, etc.
Summary of Contents for MS-810
Page 1: ...MS 810 Industrial Scanner User s Manual P N 83 000810 Rev B...
Page 22: ...Chapter 1 1 12 MS 810 Industrial Scanner User s Manual 1 Quick Start...
Page 82: ...Chapter 3 3 20 MS 810 Industrial Scanner User s Manual 3 Serial Config...
Page 98: ...Chapter 4 4 16 MS 810 Industrial Scanner User s Manual 4 Utilities...
Page 138: ...Chapter A A 40 MS 810 Industrial Scanner User s Manual Appendices...
Page 144: ...I 6 MS 810 Industrial Scanner User s Manual Index Index...