Reset
MS-810 Industrial Scanner User’s Manual
4-11
4–Ut
ili
ties
Reset
Important
: All <A> and <Z> commands must be followed by a one second delay
before any operations, commands, or reads can be processed.
Reset
Initializes all serial configuration commands in
RAM and resets all counters and operating
parameters.
Note
:
Software Reset will reset all counters. You
should record all data that you wish to save prior
to sending this command.
Associated serial command:
<A>
Reset/Restore Default
Restores the ROM default values to RAM then ini-
tializes them. Does not effect Scanner Type,
Scans per Second, or Gain Adjustment.
Associated serial command:
<Ad>
Reset/Read NOVRAM
Reads the NOVRAM settings then initializes them
to RAM.
Associated serial command:
<An>
Initialize
<
A
>
RAM
ROM
NOVRAM
RAM
Initialize
<
Ad
>
ROM
NOVRAM
Initialize
<
An
>
RAM
NOVRAM
ROM