Chapter 3
3-10
MS-810 Industrial Scanner User’s Manual
3–Ser
ial
Conf
ig.
Operation Commands
Triggering Mode
Format: <
Kg
triggering mode,filter time>
Example: To select External Edge, send
<Kg3>
.
End of Read Cycle
Format: <
Kh
end of read cycle mode,timeout>
Example: To select Timeout and change the timeout value to 6 seconds, send
<Kh0,600>
.
Serial Trigger Character
Format: <
Ki
serial trigger character>
1
Example: To define the Serial Trigger Character as a lowercase c, send
<Kic>
.
triggering mode:
0 = Continuous Read
1 = Continuous Read 1 Output
2 = External Level
3 = External Edge
4 = Serial Data
5 = Serial Data & Edge
trigger filter time (in 128 µs
increments):
Default is
78
(9984 µs; approx. 10
ms)
Any number between 2 and 255.
end of read cycle mode:
0 = Timeout
1 = New Trigger
2 = Timeout & New Trigger
timeout (in 10 millisecond increments):
Default is
100
(one second).
Any number between 0 and 65535.
serial trigger character:
Default is
^]
.
Any available ASCII character (see “ASCII Table with Control Charac-
ters” on page A-10).
1. Avoid selecting a serial trigger character that is also an operational command. For example, an
uppercase C cannot be used as a serial trigger character because it is the operational command
for Enter Decode Rate Test. However, a lowercase c could be used without initiating the decode
rate test.
Summary of Contents for MS-810
Page 1: ...MS 810 Industrial Scanner User s Manual P N 83 000810 Rev B...
Page 22: ...Chapter 1 1 12 MS 810 Industrial Scanner User s Manual 1 Quick Start...
Page 82: ...Chapter 3 3 20 MS 810 Industrial Scanner User s Manual 3 Serial Config...
Page 98: ...Chapter 4 4 16 MS 810 Industrial Scanner User s Manual 4 Utilities...
Page 138: ...Chapter A A 40 MS 810 Industrial Scanner User s Manual Appendices...
Page 144: ...I 6 MS 810 Industrial Scanner User s Manual Index Index...