Counters
MS-810 Industrial Scanner User’s Manual
4-7
4–Ut
ili
ties
Counters
Counter commands can be a numeric value from 00000 to 65,535. After reaching the
maximum numeric limit of 65,535, an error message will be displayed and the counter
will automatically rollover and start counting again at 00000. To obtain the cumulative
total of counts after the rollover has occurred, add 65,536 per each rollover (the scan-
ner does not keep track of the number of rollovers) to the current count.
Note
: All counter values will be lost if power is recycled to the scanner or the scanner
receives a reset or save command.
Clicking Reset for any counter will reset that counter to 0.
Clicking Request for any counter will return the current number for that counter.
Noread Counter
Clicking Request displays the total number of noreads that have occurred since the last
reset.
Associated serial command:
<N>
Noread Counter Reset
Clicking Reset sets Noread Counter to 00000.
Associated serial command:
<O>
Trigger Counter
Clicking Request displays the total number of triggers since the last reset.
Associated serial command:
<T>
Trigger Counter Reset
Clicking Reset sets the trigger counter to 00000.
Associated serial command:
<U>
Match Counter (or Good Read Counter)
Clicking Request displays the total number of good reads matching the master label or,
if Master Label is not enabled, the number of good reads since the last reset. This
Summary of Contents for MS-810
Page 1: ...MS 810 Industrial Scanner User s Manual P N 83 000810 Rev B...
Page 22: ...Chapter 1 1 12 MS 810 Industrial Scanner User s Manual 1 Quick Start...
Page 82: ...Chapter 3 3 20 MS 810 Industrial Scanner User s Manual 3 Serial Config...
Page 98: ...Chapter 4 4 16 MS 810 Industrial Scanner User s Manual 4 Utilities...
Page 138: ...Chapter A A 40 MS 810 Industrial Scanner User s Manual Appendices...
Page 144: ...I 6 MS 810 Industrial Scanner User s Manual Index Index...