Special 5 VDC MS-810
MS-810 Industrial Scanner User’s Manual
A-21
Appe
ndices
Appendix H — Special 5 VDC MS-810
A 5 Volt version of the MS-810 is available for special applications which requires the
scanner to have 5 volts input or connections congruent with the IB-105 adaptor box.
shows a 5V system with an IB-105 and an auxiliary monitor (via aux port).
Appendix I — “Using the IB-105.”
)
Power Supply Requirements: Input +5 VDC, ±4% regulated @ 480 mA with 200 mV
p-p max. ripple.
Table A-5 15-pin High-density D-subminiature Connector for 5 V Special Only
Pin #
Function
Pin #
Function
1
+5 VDC (in)
9
Trigger (in) from 3V to 24V
2
Transmit data (RS-232) (out)
10
CTS
3
Receive data (RS-232) (in)
11
NC
4
Signal ground (RS-232)
12
New master
5
NC
13
Chassis ground
6
RTS
14
Relay-2 Driver (out). Can sink 10 mA
and source 2 mA.
7
Relay-1 Driver (out). Can sink 10 mA
and source 2 mA.
a
a. Relay-1 output also causes closure of a relay in the IB-105 box, accessible through pin 15 of the
IB-105 host connector (see
Table A-9, “IB-105 D-sub Host Connector”
15
NC
8
Default configuration (in)
Bar-coded
item flow
IB-105
To power supply
External Object
Detector
MS-810
Scanner
Host
Auxilliary
Monitor
2 outputs from
internal relays
Figure A-8 5 Volt Setup with Auxiliary Monitor
5
10
15
11
1
6
Figure A-8 15-pin Connector
Summary of Contents for MS-810
Page 1: ...MS 810 Industrial Scanner User s Manual P N 83 000810 Rev B...
Page 22: ...Chapter 1 1 12 MS 810 Industrial Scanner User s Manual 1 Quick Start...
Page 82: ...Chapter 3 3 20 MS 810 Industrial Scanner User s Manual 3 Serial Config...
Page 98: ...Chapter 4 4 16 MS 810 Industrial Scanner User s Manual 4 Utilities...
Page 138: ...Chapter A A 40 MS 810 Industrial Scanner User s Manual Appendices...
Page 144: ...I 6 MS 810 Industrial Scanner User s Manual Index Index...