Chapter 4
4-4
MS-810 Industrial Scanner User’s Manual
4
–
U
ti
lit
ie
s
End Read Rate Test
Clicking
Stop
ends both the Percent test and the Decodes/Second test for both single
and multi-label.
Associated serial command:
<J>
Extended Mode
Choosing any of the Read Rate modes along with
Extended Mode
affects both single
and multiple labels. It instructs the scanner to output the transition data along with the
data from the latest test command sent. For example, enabling extended mode along
with single or multiple decodes per second will cause the decode rate, label data, and
transition data to be displayed.
Associated serial command:
<Ce>
after
<C>
,
<Cs>
,
<C>,
or
<Cs>
Note
:
The <Ce> command has no immediate effect if not preceded by <C>, <Cs>,
<C>, or <Cs>.
Reflectance Threshold
Number of Label Bar
Label Information
Decode Rate
per Second
* Example shows output when Postamble is enabled and defined as a carriage return and a line feed.
347 Decodes/Sec 0071486026624 REF= 0 TRANS= 38
488 Decodes/Sec 0071486026624 REF= 0 TRANS= 37
488 Decodes/Sec 0071486026624 REF= 0 TRANS= 37
447 Decodes/Sec 0071486026624 REF= 0 TRANS= 33
Summary of Contents for MS-810
Page 1: ...MS 810 Industrial Scanner User s Manual P N 83 000810 Rev B...
Page 22: ...Chapter 1 1 12 MS 810 Industrial Scanner User s Manual 1 Quick Start...
Page 82: ...Chapter 3 3 20 MS 810 Industrial Scanner User s Manual 3 Serial Config...
Page 98: ...Chapter 4 4 16 MS 810 Industrial Scanner User s Manual 4 Utilities...
Page 138: ...Chapter A A 40 MS 810 Industrial Scanner User s Manual Appendices...
Page 144: ...I 6 MS 810 Industrial Scanner User s Manual Index Index...