Chapter 2
2-34
MS-810 Industrial Scanner User’s Manual
2–Menu Conf
ig
.
Output On
Default:
Mismatch or Noread
Options:
Mismatch or Noread, Match, Mismatch, Noread
Note
:
If Output On is set to Mismatch or Noread, Match, or Mismatch, a relay pulse
will not output unless Match Code Type (
) is not disabled and a master
label is downloaded into memory (
).
Note:
To send a pulse on a Good Read, enable Match and disable Match Code Type
(see
“Match Code Type” on page 2-22
).
Allows you to set the conditions that will output a relay pulse either to pin 7 (Relay-1) or
to pin 14 (Relay-2).
Mismatch or Noread
Sends a pulse when the label's data does not match that of the master label or the
label is not decoded before the end of the read cycle.
Match (or Good Read)
Sends a pulse when the decoded label matches the master label. (To send the pulse
on a good read, disable Match Code Type on
.)
Mismatch
Sends a pulse when the label’s data does not match that of the master label.
Noread
Sends a pulse when the label’s data is not decoded before the end of the read cycle.
Polarity
Default:
Negative
Options:
Negative, Positive
Allows you to choose between positive and negative output signals for the relay out-
put pin that is enabled.
Pulse Width (in 10 ms incs)
Default:
5
(.05 seconds). Corresponds to 50 ms displayed in the menu.
Options: 0 to 255 (0 to 2.55 seconds). Divide the number to be entered by 100 for
time in seconds.
Allows you to set the duration of the good match/noread output signals at the relay
output pin that is enabled.
Note
:
After completing changes to Output On, Polarity, and Pulse Width, press
M
to
advance to Bar Code Output and continue scrolling through the Scanner Output
options.
Summary of Contents for MS-810
Page 1: ...MS 810 Industrial Scanner User s Manual P N 83 000810 Rev B...
Page 22: ...Chapter 1 1 12 MS 810 Industrial Scanner User s Manual 1 Quick Start...
Page 82: ...Chapter 3 3 20 MS 810 Industrial Scanner User s Manual 3 Serial Config...
Page 98: ...Chapter 4 4 16 MS 810 Industrial Scanner User s Manual 4 Utilities...
Page 138: ...Chapter A A 40 MS 810 Industrial Scanner User s Manual Appendices...
Page 144: ...I 6 MS 810 Industrial Scanner User s Manual Index Index...