Chapter 3
3-12
MS-810 Industrial Scanner User’s Manual
3–Ser
ial
Conf
ig.
Example: To enable Match Code Type for Sequential, set Sequential Matching for Dec-
rement, and enable Sequence on Every Mismatch, send
<Kn2,1,,,,,1>
.
New Master Pin
Format: <
Kz
status>
Example: To enable New Master Pin, send
<Kz1>
.
Number of Labels
Format: <
KL
number,multilabel separator>
Example: To change Number of Labels to 3, send
<KL3>
.
Operations Status Request
Format:
<KV?>
Returns status of each command in the group.
status:
0 = Disabled
1 = Enabled
number of labels:
Default is 1
.
Any number from 1 to 6
multilabel separator:
Default is ,
.
Any valid ASCII character