Chapter 3
3-16
MS-810 Industrial Scanner User’s Manual
3–Ser
ial
Conf
ig.
Output Commands
Relay-1
Format: <
Kv
output on,polarity,pulse width,# before output>
Example: To set Relay-1 to Mismatch and change Pulse Width to 40 ms, and # Before
Output to 5, send
<Kv2,0,4,5>
or
<Kv2,,4,5>
.
Relay-2
Format: <
Kw
output on,polarity,pulse width,# before output>
Example: To set Relay-2 to Mismatch and change Pulse Width to 40 ms, send
<Kw2,0,4>
or
<Kw2,,4>
.
Bar Code Output
Format: <
Kl
status,when to output>
Example: To set When to Output to End of Read Cycle, send
<Kl3,1>
.
output on (mode):
0 = Mismatch or Noread
1 = Match (or Good Read)
2 = Mismatch
3 = Noread
polarity:
0 = Negative
1 = Positive
pulse width:
Default is
5
(50 ms).
0 to 255
# before
output:
Default is
1.
1 to 255
output on (mode):
0 = Mismatch or Noread
1 = Match (or Good Read)
2 = Mismatch
3 = Noread
polarity:
0 = Negative
1 = Positive
pulse width:
Default is
5
(50 ms).
0 to 255
# before
output:
Default is
1.
1 to 255
status:
0 = Disabled
1 = Match
2 = Mismatch
3 = Good Read
when to output:
0 = As Soon As Possible
1 = End of Read Cycle
Summary of Contents for MS-810
Page 1: ...MS 810 Industrial Scanner User s Manual P N 83 000810 Rev B...
Page 22: ...Chapter 1 1 12 MS 810 Industrial Scanner User s Manual 1 Quick Start...
Page 82: ...Chapter 3 3 20 MS 810 Industrial Scanner User s Manual 3 Serial Config...
Page 98: ...Chapter 4 4 16 MS 810 Industrial Scanner User s Manual 4 Utilities...
Page 138: ...Chapter A A 40 MS 810 Industrial Scanner User s Manual Appendices...
Page 144: ...I 6 MS 810 Industrial Scanner User s Manual Index Index...