Protocol Commands
MS-810 Industrial Scanner User’s Manual
3-9
3–Ser
ial
Conf
ig.
Response Timeout
Format: <
KA
timeout setting>
1
Example: To change Response Timeout to 30 ms, send
<KA30>
.
Intercharacter Delay
Format: <
KB
time interval>
Example: To change Inter-character Delay to 30 ms, send
<KB30>
.
timeout setting:
Default is
12
(ms).
Any number from 0 to 65,000 (a zero causes an indefinite wait).
1. For use with Microscan’s IB-105.
time interval (between characters in milliseconds):
Default is
0
.
Any number from 0 to 255.