Using the IB-105
MS-810 Industrial Scanner User’s Manual
A-27
Appe
ndices
OPTION -05: RS-422 LAN to RS-232 Terminal
1
In this configuration the Mode switch must be IN for proper operation.
This is a special configuration to convert RS-422 signals back to RS-232. The main pur-
pose for this configuration is to use two IB-105’s, one to convert the scanner communi-
cations to RS-422 and one to convert these signals back to RS-232 (this configuration)
for long distance communications (up to 4000 feet).
See
“IB-105 D-sub Host Connector” on page A-23
and
for pinouts. The LAN cable pinout must be as follows:
The signal routing is from the LAN connector to the LAN connector. The scanner and
trigger connector are not used in this configuration.
1. Access to the configuration menus of a scanner that is in a polled mode can be forced (without
defaulting) by sending the
<D>
command from an auxiliary terminal via the auxiliary RS-232
port.
Scanner
Host
IB-105
RS-232
RS-232
IB-105
RS-422
(-05)
(-02 or -04)
1
2
3
4
5
1
2
3
4
5
#1 IB-105 RS-485/422
Connector
#2 IB-105 RS-485/422
Host Connector
LAN RJ-12 cable
Summary of Contents for MS-810
Page 1: ...MS 810 Industrial Scanner User s Manual P N 83 000810 Rev B...
Page 22: ...Chapter 1 1 12 MS 810 Industrial Scanner User s Manual 1 Quick Start...
Page 82: ...Chapter 3 3 20 MS 810 Industrial Scanner User s Manual 3 Serial Config...
Page 98: ...Chapter 4 4 16 MS 810 Industrial Scanner User s Manual 4 Utilities...
Page 138: ...Chapter A A 40 MS 810 Industrial Scanner User s Manual Appendices...
Page 144: ...I 6 MS 810 Industrial Scanner User s Manual Index Index...