Chapter 2
2-30
MS-810 Industrial Scanner User’s Manual
2–Menu Conf
ig
.
Note
: If additional labels—other than the main or supplemental—will be read in the
same read cycle, Number of Labels should be set accordingly.
Separator
Default:
Disabled
Options:
Disabled, Enabled
Allows you to insert a character between the standard UPC or EAN code and the sup-
plemental code when Supplementals is set to Required.
Separator (character)
Default:
,
(comma)
Options:
Any ASCII character.
Allows you to change the separator character from a comma to a new value.
Note
: UPC separator character, if used, must be different than the multilabel separator.
Code 128
Default:
Disabled
Options:
Disabled, Enabled
Fixed Code Length
Default:
Disabled
Options:
Disabled, Enabled
Allows you to increase data integrity by ensuring that only one label length will be
accepted.
Code Length
Default:
10
Options:
1 to 64
Note
:
Fixed Code Length must be enabled for Code Length to take effect.
Allows you to specify the exact number of characters that the scanner will recognize. The
scanner will ignore any code not having the specified length.
Narrow Margins
Default:
Disabled
Options: Disabled,
Enabled
Allows the scanner to read bar codes with quiet zones less than 10 times the width of the
narrow bar element. “Quiet zone” is the space at the leading and trailing ends of a label.
Each quiet zone can be as narrow as only five times the width of the narrow bar element
when Narrow Margins is enabled.
Summary of Contents for MS-810
Page 1: ...MS 810 Industrial Scanner User s Manual P N 83 000810 Rev B...
Page 22: ...Chapter 1 1 12 MS 810 Industrial Scanner User s Manual 1 Quick Start...
Page 82: ...Chapter 3 3 20 MS 810 Industrial Scanner User s Manual 3 Serial Config...
Page 98: ...Chapter 4 4 16 MS 810 Industrial Scanner User s Manual 4 Utilities...
Page 138: ...Chapter A A 40 MS 810 Industrial Scanner User s Manual Appendices...
Page 144: ...I 6 MS 810 Industrial Scanner User s Manual Index Index...