Page 74
Errors, Repairs
confocalDT 24x1
Guide the locking pin of the sensor cable into the
connector cavity.
Screw together the sensor's connector and socket
ends.
Screw the protective sleeve back onto the sen-
sor.
Run the dark reference, see Chap.
.
7.3
Changing the Protective Glass for IFS2405 and IFS2406 Sensors
Changing the protective glass is required for
-
irreversible pollution.
-
scratches.
i
Do not use the sensor without a protective glass, because this leads to a lower
measurement accuracy.
7.3.1
IFS2405/IFS2406
Loose the front socket with the protective glass from the sensor.
Remove the seal and place the O-ring into the frame groove of the new socket.
Screw the new socket with the protective glass back onto the sensor.
7.3.2
IFS2406/90-2.5
Loose the grub screws on the sensor, see
, and slide the protective glass
aside, see
Grub screws
Fig. 67 View on sensor from above
Fig. 68 View on sensor from below
Slide the new protective glass flush back and clamp the protective glass with the
two grub screws again firmly.