Page 61
Advanced Settings
confocalDT 24x1
6.6
Switching Outputs
Assignment of the
switch outputs
(digital I/O)
Switching output “Error 1”
Switching output “Error 2”
Error intensity (F1) /
Outside of measuring range (F2) /
F1 or F2 / Lower limit value (Gr1) /
Upper limit value (Gr2) / Gr1 or Gr2
/ No output
Limit value settings
Lower limit value (in mm)
Value
Upper limit value (in mm)
Value
Measurement value that
belongs to limit values
Distance 1, 2 /
Distance 3 ... 6 /
Difference 1 - 2
/ Difference 1 - 3 up
5 - 6
Switch threshold of
the error outputs
High active / low active
6.6.1
Assignment of the Switch Outputs (digital I/O)
Switching outputs “Error 1” and “Error 2” of the “Digital I/O” terminal block can be indi-
vidually assigned to different errors and thresholds.
Per default, “Error 1” is assigned to intensity errors (F1, peak too high or too low), and
“Error 2” corresponds to the signal being outside the measuring range (F2).
6.6.2
Limit Value Settings
You can also use the “Error 1” and “Error 2” switching outputs to monitor threshold val-
ues. In this case, enter lower and upper limit values (in mm).
6.6.3
Switch Threshold of the Error Outputs
The switching logic for errors or out-of-range results can be set to
high active
or
low
active
.
High active
Low active
Switching output
active
Error 1/2
5 V
0 V
Time
Switching output
active
Error 1/2
5 V
0 V
Time
Fig. 48 Behavior of the binary outputs Error 1 and Error 2
Selecting the switching logic is different from selecting a level by using a screw terminal
bridge on the front of the controller, see Chap.
.
You can set the screw terminal voltage level to 5 V or 24 V.