Section 6 - Storage
90-899883234 JANUARY 2008
Page 119
7. Immediately remove the blue drain plug from the side of the thermostat housing or the
heat exchanger. This must be removed within 30 seconds to properly vent the cooling
system.
6124
a
b
c
d
6125
a
b
c
d
Closed Cooled Models
Seawater Cooled Models
a -
Blue drain plug location
b -
Blue air pump
c -
Air manifold
d -
Green indicators
8. Verify that water is draining from each opening. If not, use the
Three Point Manual
Drain System
instructions.
a
b
6133
a -
Port side drain location
b -
Starboard side drain location
9. Allow the system to drain for a minimum of five minutes. Pump air as necessary to keep
the green indicators extended.
10. Crank the engine over slightly with the starter motor to purge any water trapped in the
seawater pump. Do not allow engine to start.
11. Reinstall the blue drain plug in the thermostat housing or heat exchanger.
12. Remove the air pump from the air manifold and return it to the mounting bracket.
13. Mercury MerCruiser recommends leaving the drain system open while transporting the
boat or while performing other maintenance. This helps ensure that all water is drained.
Summary of Contents for Axius 350 MAG
Page 26: ...Section 1 Warranty Notes Page 18 90 899883234 JANUARY 2008 ...
Page 42: ...Section 2 Getting to Know Your Power Package Notes Page 34 90 899883234 JANUARY 2008 ...
Page 76: ...Section 4 Specifications Notes Page 68 90 899883234 JANUARY 2008 ...
Page 120: ...Section 5 Maintenance Notes Page 112 90 899883234 JANUARY 2008 ...
Page 138: ...Section 6 Storage Notes Page 130 90 899883234 JANUARY 2008 ...