Section 5 - Maintenance
Page 86
90-899883234 JANUARY 2008
3. Remove the flame arrestor.
6110
a
b
c
d
e
f
a -
Engine cover knob
b -
Engine cover
c -
Nuts, flame arrestor
d -
Cover mount bracket
e -
Flame arrestor
f -
Crankcase ventilation hose
4. Clean the flame arrestor with warm water and a mild detergent.
5. Inspect the flame arrestor for holes, cracks or deterioration. Replace if necessary.
6. Allow the flame arrestor to air dry completely before use.
7. Clean the crankcase ventilation hose with warm water and a mild detergent. Dry with
compressed air or allow to air dry completely.
8. Inspect the crankcase ventilation hose for cracks or deterioration. Replace if necessary.
9. Install the flame arrestor and flame arrestor bracket. Torque the flame arrestor bracket
nuts.
Description
Nm
lb. in.
lb. ft.
Flame arrestor bracket nut
12
106
–
10. Connect the crankcase ventilation hose to the fitting on the flame arrestor and valve
cover.
11. Install the engine cover.
Positive Crankcase Ventilation Valve (PCV)
Inspection
IMPORTANT: You cannot clean the PCV valve. Replace the PCV valve if it is defective or
sticking.
1. Remove the PCV valve from the port valve cover.
Summary of Contents for Axius 350 MAG
Page 26: ...Section 1 Warranty Notes Page 18 90 899883234 JANUARY 2008 ...
Page 42: ...Section 2 Getting to Know Your Power Package Notes Page 34 90 899883234 JANUARY 2008 ...
Page 76: ...Section 4 Specifications Notes Page 68 90 899883234 JANUARY 2008 ...
Page 120: ...Section 5 Maintenance Notes Page 112 90 899883234 JANUARY 2008 ...
Page 138: ...Section 6 Storage Notes Page 130 90 899883234 JANUARY 2008 ...