My XCi has power problems
WARNING: Before troubleshooting power problems, ensure that you've pressed a
button on the front of the enclosure to "wake-up" the XCi device. The most common
"reason" for a perceived power issue is that the LCD "appears" to be dead.
Symptom
Cause
Remedy
Low/Flat
battery
(consistently <12 V)
Old battery
Replace battery
Weak or no solar charge
Check solar panel undamaged
Check solar panel for dirt and
clean if necessary
Check wiring of solar panel is
No external power
Check trickle charger is turned
on
Check wiring of trickle charger
Measurement interval too short
Integration period too long
Decrease integration period
Too many sensors for power
supply
Check the "
"
None of
the above
XCi must be drawing high cur-
rent
for service
MACE XCi User Manual - 250 -