No. of zones
Enter the number of "flow regimes" that have had velocity calibrations performed. A maximum of four (4)
zones is applicable
Factor
The calculated ratio to be applied to the "
Velocity
" channel data.
Depth
Enter the zone depth limits here. For example,
"
Factor ratio
" for "
Zone 4
" will be applied for stream depths between zero (0) and 0.3m.
"
Factor ratio
" for "
Zone 3
" will be applied for stream depths between 0.3m and 0.7m.
"
Factor ratio
" for "
Zone 2
" will be applied for stream depths between 0.7m and 0.8m.
"
Factor ratio
" for "
Zone 1
" will be applied for stream depths between 0.8m and maximum depth.
NOTE: All depths as measured by the associated "
Depth
" channel