Wiring an SDI-12 Master card
After installing the card, connect it to the SDI-12 sensor using either of the two 3-way terminal blocks. Two
terminal blocks are provided for user convenience when wiring multiple sensors.
The “
Transparent Mode
” port allows you to send extended SDI-12 commands to sensors using a terminal
program such as Microsoft
®
HyperTerminal
®
.
Connect the PC running the terminal program using a serial cable (or USB-to-serial adapter).
The port settings in the terminal program should be set to the following:
l
9600 baud
l
8 data bits
l
No parity
l
1 stop bit
l
No flow control
NOTE: When a transparent mode session is in progress the LED Transparent Mode
Indicator will light.
HyperTerminal is a registered trademark of Microsoft Corporation in the United States and other countries.