Volume increment
The incremental value at which a pulse will be sent. In the example above, a pulse will be sent whenever an
increment of 1 Megalitre is totalised.
WARNING: A maximum of 10 pulses per second may be sent per measurement
interval. For example, during a measurement interval of three minutes (180 seconds)
a maximum of 1,800 pulses can be sent. If the XCi device has not sent all pulses by
the time of the next measurement, pulses WILL be lost.
Click “
Apply
” to save the settings then click “
Exit
” to return to the “
Configure outputs
” dialogue box.
Test a "Pulse" output
From the "
Edit Total pulse output
" dialogue box, click "
Test
".
1. Enter the "
Number of pulses
" that you wish to send to the connected "
pulse counting device
".
2. Click "
Send
" and the pulses will be sent.
WARNING: A maximum of 10 pulses per second may be sent per measurement
interval. For example, during a measurement interval of three minutes (180 seconds)
a maximum of 1,800 pulses can be sent. If the XCi device has not sent all pulses by
the time of the next measurement, pulses WILL be lost.
Remove a "Pulse" output
1. From the "
Configure outputs
" dialogue box, highlight the output you wish to remove and then click
"
Remove
".
2. You will be prompted to confirm the removal. Click "
Yes
" and the output will be removed.
MACE XCi User Manual - 238 -
Summary of Contents for HydroMace XCi
Page 1: ......
Page 13: ...MACE XCi User Manual 13...
Page 19: ...MACE XCi User Manual 19...
Page 33: ...MACE XCi User Manual 33...
Page 36: ...MACE XCi User Manual 36...
Page 167: ...NOTE None of these parameters can be edited MACE XCi User Manual 167...
Page 182: ...MACE XCi User Manual 182...
Page 187: ...MACE XCi User Manual 187...
Page 265: ...MACE XCi User Manual 265...