NOTE: These values should have been acquired by running the SDI-12 Master
utility.
Sensor Address
Enter the unique sensor address (0 to 9) as acquired using the "
Address query
".
Value number
Enter the "
Value number
" as acquired using a "
Send data
" or "
Read data
" command.
3. Click "
Apply
" and the "
Edit SDI-12 sensor settings
" dialogue box will open.
SDI-12 sensor settings
Address
This shows the sensor address on the SDI-12 bus.
Command
This shows the current SDI-12 command that will be sent to the sensor when starting a measuring sequence.
By default this will be a “
C
” command.
Use ‘R’ command
If a concurrent measurement (C) is not to be initiated, check this box.
Use CRC
To enhance error detection, check this box and the data will be returned with a 16-bit cyclic redundancy check
(CRC).
Command extension
Command extensions provide a means to request different types of measurements or sensor instructions.
MACE XCi User Manual - 176 -