"User defined"
WARNING: It is imperative that the correct sensor address be entered into the
“
Address
” field prior to sending this command.
Enter the known address of the sensor you wish to command in the “
Address
” field. Enter a valid SDI-12
command into the text field and click “
Send command
”. The sensor will respond (if active) in the
“
Response
” field.
Example 1 - The "
C
" command
In the example , the sensor on Address “
1
” of the SDI-12 bus has responded to a “
C
” command with the
Response “
101504
".
The 1st digit is the Address identifier (
1
). The 2nd, 3rd and 4th digits are the time the sensor requires to
take a measurement (
015
seconds). The 5th and 6th digits are the number of measurement values that
will be sent (
04
).
WARNING: The user MUST ensure that the time required for the sensor to take a
measurement is noted BEFORE adding
MACE XCi User Manual - 222 -