5.4
Activating Cab Display Lockouts
Some header configuration settings in the windrower
’
s cab display module (CDM) can be locked, so that Operators lacking
the proper authorization will be unable to change these settings. Use this feature to keep header settings constant when
there are multiple Operators operating the windrower.
NOTE:
FUNCTION LOCKED will appear on the CDM when a header function switch which has been locked out is pressed.
5.4.1
Activating Header Tilt Control Lockout
Enabling the header tilt control lockout in the windrower
’
s cab display module (CDM) prevents unauthorized Operators
from changing the angle of the attached header.
NOTE:
•
The header
MUST
be attached to the windrower to perform this procedure. The cab display module (CDM)
automatically adjusts its programming for each header.
1011786
CXXX
EXXX
WINDROWER SETUP?
NO/YES
A
B
C
Figure 5.55: CDM Programming Buttons
1.
Turn the ignition key to the RUN position, or start the
engine.
2.
Press PROGRAM (A) and SELECT (C) on the CDM to enter
programming mode.
•
WINDROWER SETUP? will appear on the upper line.
•
NO/YES will appear on the lower line.
3.
Press right arrow (B) to select YES. Press SELECT (C).
•
SET KNIFE SPEED? will appear on the upper line.
1011824
CXXX
EXXX
NO/YES
SET CONTROL LOCKS?
B
A
Figure 5.56: Control Locks
4.
Press SELECT (B) until SET CONTROL LOCKS? appears on the
upper line.
•
NO/YES will appear on the lower line.
5.
Press right arrow (A) to select YES. Press SELECT (B).