
215794
101
Revision A
1011781
CXXX
EXXX
CALIBRATING FLOAT
PRESS FLOAT + TO START
C
B
A
Figure 5.93: Header Float Display
4.
Press right arrow (B) to select YES. Press SELECT (C).
•
TO CALIBRATE SELECT will appear on the upper line.
5.
Press left arrow (A) or right arrow (B) until HEADER FLOAT
appears on the lower line. Press SELECT (C).
•
CALIBRATING FLOAT will appear on the upper line.
•
PRESS FLOAT + TO START will appear on the lower line.
1011789
CXXX
EXXX
CALIBRATING FLOAT
FLOAT ( + ) HOLD
A
Figure 5.94: Positive Header Float Display
6.
Press and hold FLOAT + button (A) on the CDM.
•
CALIBRATING FLOAT will appear on the upper line.
•
FLOAT ( + ) HOLD will appear on the lower line.
NOTE:
The word HOLD will flash during calibration. FLOAT ( + )
DONE will appear on the lower line once calibration is
complete.
7.
Release FLOAT + button (A).
•
CALIBRATING FLOAT will appear on the upper line.
•
FLOAT (
–
) HOLD will appear on the lower line.
1011791
CXXX
EXXX
CALIBRATING FLOAT
FLOAT ( - ) HOLD
A
Figure 5.95: Negative Header Float Display
8.
Press and hold FLOAT
–
button (A) on the CDM.
•
CALIBRATING FLOAT will appear on the upper line.
•
FLOAT (
–
) HOLD will appear on the lower line.
NOTE:
The word HOLD will flash during calibration. HDR FLOAT
COMPLETE will appear on the lower line once calibration is
complete.
9.
Release FLOAT
–
button (A).
•
TO CALIBRATE SELECT will appear on the upper line.
•
HEADER FLOAT will appear on the lower line.
10. Press the right arrow to select the next header sensor calibration or select STOP & EXIT. Press SELECT.
11. Press PROGRAM to exit programming mode.