215794
100
Revision A
5.6.3
Calibrating Header Float Sensors
The header float sensors can be calibrated by accessing the cab display module
’
s (CDM) WINDROWER SETUP menu. The
calibration procedure must be completed for the sensors to be correctly calibrated.
NOTE:
•
The header must be attached to the windrower to perform this procedure. The cab display module (CDM) automatically
adjusts its programming for each header.
•
Use the left or right FLOAT buttons on the CDM to perform this procedure.
WARNING
Check to be sure all bystanders have cleared the area.
1021948
A
Figure 5.91: Float Pin
–
Right Side
IMPORTANT:
Ensure that float pins (A) are installed in the working position.
1011772
C###
E###
WINDROWER SETUP?
NO/YES
A
B
Figure 5.92: CDM Programming Buttons
1.
Start the engine.
2.
Press PROGRAM (A) and SELECT (B) simultaneously on the
CDM to enter programming mode.
•
WINDROWER SETUP? will appear on the upper line.
3.
Press SELECT (B) until CALIBRATE SENSORS? appears on the
upper line.
•
NO/YES will appear on the lower line.