215794
98
Revision A
5.6.2
Calibrating Header Tilt Sensor
The header tilt sensor can be calibrated by accessing the cab display module
’
s (CDM) WINDROWER SETUP menu. The
calibration procedure must be completed for the sensor to be correctly calibrated.
NOTE:
•
The header must be attached to the windrower to perform this procedure. The cab display module (CDM) automatically
adjusts its programming for each header.
•
The engine must be running to perform this procedure.
WARNING
Check to be sure all bystanders have cleared the area.
1011772
C###
E###
WINDROWER SETUP?
NO/YES
A
B
Figure 5.87: CDM Programming Buttons
1.
Start the engine.
2.
Press PROGRAM (A) and SELECT (B) simultaneously on the
CDM to enter programming mode.
•
WINDROWER SETUP? will appear on the upper line.
3.
Press SELECT (B) until CALIBRATE SENSORS? appears on the
upper line.
•
NO/YES will appear on the lower line.
1011779
HDR TILT SENSOR CAL
EXTEND TILT TO START
CXXX
EXXX
C
B
A
Figure 5.88: Header Tilt Calibration
4.
Press right arrow (B) to select YES. Press SELECT (C).
•
TO CALIBRATE SELECT will appear in the upper line.
5.
Press left arrow (A) or right arrow (B) until HEADER TILT
appears on the lower line. Press SELECT (C).
•
HDR TILT SENSOR CAL will appear on the upper line.
•
EXTEND TILT TO START will appear on the lower line.